2021 High quality Acid-base Salt Concentration Sensor - Online Residual Chlorine Meter T6050 – Chunye Detail:
Function
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.
Typical Use
This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine and temperature value in aqueous solution.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range
Residual Chlorine: 0~20ppm; 0~20mg/L;
Temperature: 0~150℃.
Features
1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.
2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.
3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.
4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.
5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.
6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.
Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method

Technical specifications
| Measurement range | 0.005~20.00mg/L ; 0.005~20.00ppm |
| Measurement unit | Potentiometric method |
| Resolution | 0.001mg/L ; 0.001ppm |
| Basic error | ±1%F.S
։ ˫ |
| Temperature | -10 150.0 ( Based on sensor)
˫ |
| Temperature Resolution | 0.1
˫ |
| Temperature Basic error | ±0.3
։ |
| Current output | 2 groups: 4 20mA |
| Signal output | RS485 Modbus RTU |
| Other functions | Data record &Curve display |
| Three relay control contacts | 3 groups:5A 250VAC,5A 30VDC |
| Optional power supply | 85~265VAC,9~36VDC,power consumption≤3W |
| Working conditions | No strong magnetic field interference around except the geomagnetic field.
։ ˫ |
| Working temperature | -10 60 |
| Relative humidity | ≤90% |
| Waterproof rating | IP65 |
| Weight | 0.8kg |
| Dimensions | 144×144×118mm |
| Installation opening size | 138×138mm |
| Installation methods | Panel & wall mounted or pipeline |

|
Model No. |
CS5530 |
|
Measurement method |
Tri-electrode method |
|
Measure material |
Double liquid junction,annular liquid junction |
|
Housing material/Dimensions |
PP, Glass, 120mm*Φ12.7mm |
|
Waterproof grade |
IP68 |
|
Measurement range |
0 – 5.000 mg/L, 0 – 20.00 mg/L |
|
Accuracy |
±0.05mg/L; |
|
Pressure resistance |
≤0.3Mpa |
|
Temperature compensation |
None or Customize NTC10K |
|
Temperature range |
0-50℃ |
|
Calibration |
Sample calibration |
|
Connection methods |
4 core cable |
|
Cable length |
Standard 5m cable, can be extended to 100m |
|
Installation thread |
PG13.5 |
|
Application |
Tap water, disinfectant fluid, etc. |
Product detail pictures:
Related Product Guide:
We now have our own gross sales team, style and design workforce, technical crew, QC workforce and package group. We now have strict quality manage procedures for each system. Also, all of our workers are experienced in printing industry for 2021 High quality Acid-base Salt Concentration Sensor - Online Residual Chlorine Meter T6050 – Chunye , The product will supply to all over the world, such as: Zurich, Johannesburg, Algeria, Qualified R&D engineer might be there for your consultation service and we will try our best to meet your requirements. So you should feel free to contact us for inquiries. You'll be able to send us emails or call us for small business. Also you are able to come to our business by yourself to get further knowing of us. And we are going to surely present you with the best quotation and after-sale service. We're ready to build stable and friendly relations with our merchants. To achieve mutual success, we'll make our best efforts to build a solid co-operation and transparent communication work with our companions. Above all, we're here to welcome your inquiries for any of our merchandise and service.
The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.