Suspended Solids(Sludge Concentration)/Turbidity Series

  • Digital Turbidity Sensor with Automatic Cleaning CS7833D

    Digital Turbidity Sensor with Automatic Cleaning CS7833D

    The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Digital Turbidity Sensor with Automatic Cleaning CS7832D

    Digital Turbidity Sensor with Automatic Cleaning CS7832D

    The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Digital Suspended Solids (Sludge concentration) Sensor  with Automatic Cleaning CS7863D

    Digital Suspended Solids (Sludge concentration) Sensor with Automatic Cleaning CS7863D

    The principle of the Suspended Solids (Sludge concentration) is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • CS7850D Digital Suspended Solids (Sludge concentration) Sensor

    CS7850D Digital Suspended Solids (Sludge concentration) Sensor

    The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • CS7850D Digital Suspended Solids (Sludge concentration) Sensor

    CS7850D Digital Suspended Solids (Sludge concentration) Sensor

    The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Digital Suspended Solids (Sludge concentration) Sensor  with Automatic Cleaning CS7863D

    Digital Suspended Solids (Sludge concentration) Sensor with Automatic Cleaning CS7863D

    The principle of the Suspended Solids (Sludge concentration) is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Digital Turbidity Sensor with Automatic Cleaning CS7832D

    Digital Turbidity Sensor with Automatic Cleaning CS7832D

    The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Digital Turbidity Sensor with Automatic Cleaning  CS7833D

    Digital Turbidity Sensor with Automatic Cleaning CS7833D

    The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • CS7862D Digital Suspended Solids (Sludge concentration) Sensor with Automatic Cleaning

    CS7862D Digital Suspended Solids (Sludge concentration) Sensor with Automatic Cleaning

    The principle of the Suspended Solids (Sludge concentration) is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Online Suspended Solids Meter T4075

    Online Suspended Solids Meter T4075

    The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration.According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.This instrument is an analytical measurement and control instrument with highly
    precision.Only skilled,trained or authorized person should carry out installation, setup and operation of the instrument.Ensure that the power cable is physically separated from the power supply when connection or repair.Once the safety problem occurs, make sure that the power to the instrument is off and disconnected.
  • Online Suspended Solids Meter T6075

    Online Suspended Solids Meter T6075

    The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration.According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.This instrument is an analytical measurement and control instrument with highly
    precision.Only skilled,trained or authorized person should carry out installation, setup and operation of the instrument.Ensure that the power cable is physically separated from the power supply when connection or repair.Once the safety problem occurs, make sure that the power to the instrument is off and disconnected.
  • Online Suspended Solids Meter T6575

    Online Suspended Solids Meter T6575

    The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration.
    According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Online Turbidity Meter T4070

    Online Turbidity Meter T4070

    The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.
    Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Online Turbidity Meter T6070

    Online Turbidity Meter T6070

    The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.
  • Online Turbidity Meter T6570

    Online Turbidity Meter T6570

    The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.
    Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and
12 Next > >> Page 1 / 2