Best quality Chlorine Dioxide Sensor - Online Dissolved Oxygen Meter T6042 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Innovation, excellent and reliability are the core values of our firm. These principles today more than ever form the basis of our success as an internationally active mid-size corporation for Ph Tester 10, Hot Popular Portable Suspended Solid (TSS)Meter, High Quality Portable COD Tester, "Making the Products of High Quality" is the eternal goal of our company. We make unremitting efforts to realize the goal of "We Will Always Keep in Pace with the Time".
Best quality Chlorine Dioxide Sensor - Online Dissolved Oxygen Meter T6042 – Chunye Detail:

T6042
6000-A
6000-B
Function
Industrial online dissolved oxygen meter is an online water quality monitor and control instrument with microprocessor. The instrument is equipped with different types of dissolved oxygen sensors. It is widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, food and beverage industry, environmental protection water treatment, aquaculture and other industries. The dissolved oxygen value and temperature value of water solution are continuously monitored and controlled.
Typical Use
This instrument is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries. It has the characteristics of fast response, stability, reliability, and low use cost, widely used in large-scale water plants, aeration tanks, aquaculture, and sewage treatment plants.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range

Dissolved Oxygen: 0~200ug/L, 0~20mg/L;
Customizable measuring range, displayed in ppm unit.

Online Dissolved Oxygen Meter T6042

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Carefully select materials and strictly select each circuit component, which greatly improves the stability of the circuit during long-term operation.

4.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
11
Technical specifications

Measurement range 0~200ug/L, 0~20mg/L;
Measurement unit mg/L; %
Resolution 0.01ug/L; 0.01mg/L;
Basic error ±1%F.S
Temperature -10~150℃
Temperature Resolution 0.1℃
Temperature Basic error ±0.3℃
Current Output 4~20mA,20~4mA,(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control contacts 5A 240VAC,5A 28VDC or 120VAC
Power supply (optional) 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10~60℃
Relative humidity ≤90%
IP rate IP65
Instrument Weight 0.8kg
Instrument Dimensions 144×144×118mm
Mounting hole dimensions 138*138mm
Installation methods Panel,Wall mounted,pipeline

Dissolved Oxygen Sensor

1

Model No. CS4800
Measuring Mode Polarography
Housing Material 316 Stainless steel
Waterproof Rating IP68
Measuring Range 0-20mg/L
Accuracy ±1%F.S
PressureRange ≤0.3Mpa
Temperature Compensation  NTC10K
Temperature Range 0-80℃
Calibration Anaerobic Water Calibration and Air Calibration
Connection Methods 4 core cable
Cable Length Standard 5m cable, can be extended
Installation Thread Compaction Style
Application Power plant, boiler water, etc

Product detail pictures:

Best quality Chlorine Dioxide Sensor - Online Dissolved Oxygen Meter T6042 – Chunye detail pictures

Best quality Chlorine Dioxide Sensor - Online Dissolved Oxygen Meter T6042 – Chunye detail pictures

Best quality Chlorine Dioxide Sensor - Online Dissolved Oxygen Meter T6042 – Chunye detail pictures


Related Product Guide:

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for Best quality Chlorine Dioxide Sensor - Online Dissolved Oxygen Meter T6042 – Chunye , The product will supply to all over the world, such as: Vietnam, Greece, Honduras, We guarantee that our company will try our best to reduce customer purchase cost , shorten the period of purchase , stable products quality , increase customers' satisfaction and achieve win-win situation .
  • The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Gary from Botswana - 2018.12.28 15:18
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Lynn from Rwanda - 2017.01.11 17:15
    Write your message here and send it to us