Best-Selling Online Turbidity Meter - Online Chlorine Dioxide Meter T6053 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also offer you product sourcing and flight consolidation expert services. We've our personal manufacturing unit and sourcing business. We can offer you virtually every variety of merchandise associated to our item range for Soil Ph Tester Nz, Sensor Tds Arduino, Industrial Online Nitrite ion Electrode, Adhering to the business principle of mutual benefits, we have won good reputation among our customers because of our perfect services, quality products and competitive prices. We warmly welcome customers from home and abroad to cooperate with us for common success.
Best-Selling Online Turbidity Meter - Online Chlorine Dioxide Meter T6053 – Chunye Detail:

Function

Online chlorine dioxide meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control chlorine dioxide and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The chlorine dioxide measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

A1

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S

։ ˫

Temperature -10 150.0 ( Based on sensor)

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3

։

Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.

։ ˫

Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

1

Model No.

CS5560

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

Best-Selling Online Turbidity Meter - Online Chlorine Dioxide Meter T6053 – Chunye detail pictures

Best-Selling Online Turbidity Meter - Online Chlorine Dioxide Meter T6053 – Chunye detail pictures

Best-Selling Online Turbidity Meter - Online Chlorine Dioxide Meter T6053 – Chunye detail pictures


Related Product Guide:

We always believe that one's character decides products' quality, the details decides products' quality ,with the REALISTIC,EFFICIENT AND INNOVATIVE team spirit for Best-Selling Online Turbidity Meter - Online Chlorine Dioxide Meter T6053 – Chunye , The product will supply to all over the world, such as: Italy, Germany, Belgium, We have a professional sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique products.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Abigail from Japan - 2017.12.02 14:11
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Susan from Ecuador - 2017.01.28 19:59
    Write your message here and send it to us