China Supplier Chlorophyll Sensor RS485 - Online Membrane Residual Chlorine Meter T6055 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our pursuit and company intention is usually to "Always fulfill our purchaser requirements". We go on to acquire and layout excellent high quality products for both our previous and new consumers and realize a win-win prospect for our customers too as us for Ph Metre Electrode, Dpd Test For Residual Chlorine, Ph Electrode Aquarium, We have been normally seeking forward to forming profitable company relationships with new clientele around the environment.
China Supplier Chlorophyll Sensor RS485 - Online Membrane Residual Chlorine Meter T6055 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine, pH and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm;
pH: -2~16pH;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

aaa

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Membrane
Resolution 0.001mg/L ; 0.001ppm
Basic error

±1%F.S

։

Measurement range -2 16.00pH
Measurement unit pH
Resolution 0.001pH
Basic error ±0.01pH։ ˫
Temperature -10 150.0 ( Based on sensor)˫
Temperature Resolution 0.1˫
Temperature Basic error ±0.3։
Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.։ ˫
Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

b1

Model No.

CS5763

Measurement method

Membrane

Housing material

POM+316L Stainless

Waterproof grade

IP68

Measurement range

0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

NTC10K

Temperature range

0-50℃

Calibration

Chlorine-free water, water sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

NPT3/4’’

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

China Supplier Chlorophyll Sensor RS485 - Online Membrane Residual Chlorine Meter T6055 – Chunye detail pictures

China Supplier Chlorophyll Sensor RS485 - Online Membrane Residual Chlorine Meter T6055 – Chunye detail pictures

China Supplier Chlorophyll Sensor RS485 - Online Membrane Residual Chlorine Meter T6055 – Chunye detail pictures


Related Product Guide:

To be the stage of realizing dreams of our employees! To build a happier, more united and more professional team! To reach a mutual benefit of our customers, suppliers, the society and ourselves for China Supplier Chlorophyll Sensor RS485 - Online Membrane Residual Chlorine Meter T6055 – Chunye , The product will supply to all over the world, such as: Chile, Jakarta, Swiss, Our products are mainly exported to Southeast Asia, the Middle East, North America and Europe. Our quality is surely guaranteed. If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
  • We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Christopher Mabey from Slovak Republic - 2018.06.09 12:42
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Janice from Cologne - 2017.08.18 18:38
    Write your message here and send it to us