Europe style for Digital Nitrite Sensor RS485 - Online Dissolved Oxygen Meter T6042 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We've been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We could guarantee you item excellent and aggressive price tag for Digital Oil in Water Sensor RS485, Personal Ozone Monitor, Reusable Ph Tester, We can easily offer you by far the most aggressive prices and good quality, because we've been much additional Specialist! So please will not hesitate to call us.
Europe style for Digital Nitrite Sensor RS485 - Online Dissolved Oxygen Meter T6042 – Chunye Detail:

T6042
6000-A
6000-B
Function
Industrial online dissolved oxygen meter is an online water quality monitor and control instrument with microprocessor. The instrument is equipped with different types of dissolved oxygen sensors. It is widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, food and beverage industry, environmental protection water treatment, aquaculture and other industries. The dissolved oxygen value and temperature value of water solution are continuously monitored and controlled.
Typical Use
This instrument is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries. It has the characteristics of fast response, stability, reliability, and low use cost, widely used in large-scale water plants, aeration tanks, aquaculture, and sewage treatment plants.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range

Dissolved Oxygen: 0~200ug/L, 0~20mg/L;
Customizable measuring range, displayed in ppm unit.

Online Dissolved Oxygen Meter T6042

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Carefully select materials and strictly select each circuit component, which greatly improves the stability of the circuit during long-term operation.

4.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
11
Technical specifications

Measurement range 0~200ug/L, 0~20mg/L;
Measurement unit mg/L; %
Resolution 0.01ug/L; 0.01mg/L;
Basic error ±1%F.S
Temperature -10~150℃
Temperature Resolution 0.1℃
Temperature Basic error ±0.3℃
Current Output 4~20mA,20~4mA,(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control contacts 5A 240VAC,5A 28VDC or 120VAC
Power supply (optional) 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10~60℃
Relative humidity ≤90%
IP rate IP65
Instrument Weight 0.8kg
Instrument Dimensions 144×144×118mm
Mounting hole dimensions 138*138mm
Installation methods Panel,Wall mounted,pipeline

Dissolved Oxygen Sensor

1

Model No. CS4800
Measuring Mode Polarography
Housing Material 316 Stainless steel
Waterproof Rating IP68
Measuring Range 0-20mg/L
Accuracy ±1%F.S
PressureRange ≤0.3Mpa
Temperature Compensation  NTC10K
Temperature Range 0-80℃
Calibration Anaerobic Water Calibration and Air Calibration
Connection Methods 4 core cable
Cable Length Standard 5m cable, can be extended
Installation Thread Compaction Style
Application Power plant, boiler water, etc

Product detail pictures:

Europe style for Digital Nitrite Sensor RS485 - Online Dissolved Oxygen Meter T6042 – Chunye detail pictures

Europe style for Digital Nitrite Sensor RS485 - Online Dissolved Oxygen Meter T6042 – Chunye detail pictures

Europe style for Digital Nitrite Sensor RS485 - Online Dissolved Oxygen Meter T6042 – Chunye detail pictures


Related Product Guide:

As for aggressive price ranges, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such high-quality at such price ranges we're the lowest around for Europe style for Digital Nitrite Sensor RS485 - Online Dissolved Oxygen Meter T6042 – Chunye , The product will supply to all over the world, such as: Rome, Iceland, Luxembourg, Looking forward, we will keep pace with the times, continuing to create new products. With our strong research team, advanced production facilities, scientific management and top services, we will supply high quality products to our customers worldwide. We sincerely invite you to be our business partners for mutual benefits.
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By May from Czech republic - 2018.09.29 13:24
    The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By ron gravatt from Cape Town - 2017.08.15 12:36
    Write your message here and send it to us