Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for Wireless Conductivity Sensor, Waterproof Precision Suspended Solids Sensor, Industrial Online Nitrate ion Electrode, We sincerely welcome domestic and foreign merchants who calls, letters asking, or to plants to negotiate, we will offer you quality products and the most enthusiastic service,We look forward to your visit and your cooperation.
Factory making Liquified Natural Gas pH Electrode - Online Residual Chlorine Meter T4050 – Chunye Detail:

Function

Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine and  temperature  value  in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 235*185*120mm meter size, 7.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The dissolved ozone measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

A1

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S

։ ˫

Temperature -10 150.0 ( Based on sensor)

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3

։

Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 2 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.

։ ˫

Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.6kg
Dimensions 98×98×130mm
Installation opening size 92.5×92.5mm
Installation methods Panel & wall mounted or pipeline

1

Model No.

CS5530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

Factory making Liquified Natural Gas pH Electrode - Online Residual Chlorine Meter T4050 – Chunye detail pictures

Factory making Liquified Natural Gas pH Electrode - Online Residual Chlorine Meter T4050 – Chunye detail pictures

Factory making Liquified Natural Gas pH Electrode - Online Residual Chlorine Meter T4050 – Chunye detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our firm for the long-term to create jointly with consumers for mutual reciprocity and mutual reward for Factory making Liquified Natural Gas pH Electrode - Online Residual Chlorine Meter T4050 – Chunye , The product will supply to all over the world, such as: Dominica, Bahamas, Norwegian, When you are keen on any of our goods following you view our product list, be sure to feel free to make contact with us for inquiries. You'll be able to send us emails and get in touch with us for consultation and we shall respond to you as soon as we're able to. If it's convenient, you could find out our address in our web site and come to our enterprise. or additional information of our products by yourself. We're generally ready to build lengthy and steady co-operation relations with any possible shoppers within the associated fields.
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Aaron from Turkmenistan - 2017.06.19 13:51
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Eartha from Swiss - 2018.12.10 19:03
    Write your message here and send it to us