Factory making Soil Ph Tester - Online Dissolved Ozone Meter T6558 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We are also focusing on enhancing the things administration and QC program in order that we could keep fantastic advantage within the fiercely-competitive enterprise for Electronic Soil Ph Tester, Free Chlorine And Residual Chlorine, Nitrite Sensor, We are now on the lookout ahead to even larger cooperation with abroad consumers dependant on mutual added benefits. When you are interested in almost any of our products, be sure to experience cost-free to make contact with us for more facts.
Factory making Soil Ph Tester - Online Dissolved Ozone Meter T6558 – Chunye Detail:

Function

Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. It continuous monitoring and control water quality disinfection (ozone generator matching) and other industrial processes.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 235*185*120mm meter size, 7.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The dissolved ozone measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

1

Technical specifications

Measurement range 0.005~20mg/L;0.005~20.00ppm
Measurement theory Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic error ±1%F.S
Temperature 0~50.0°C
Temperature resolution 0.1°C
Temperature accuracy ±0.3°C
Temperature compensation 0~60.0°C
Temperature compensation Manual or automatic
Electrode residual signal <1‰
Response time 25°C<60S; 35°C<30S (To attain 90%)
Stability At constant pressure and temperature, the weekly drift<2%F•S;
Current output Two:4~20mA,20~4mA,0~20mA(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control set-points Three:3A 250VAC,3A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference except the geomagnetic field.
Working temperature -10~60°C
Relative humidity ≤90%
Waterproof rating IP65
Weight 1.5kg
Dimensions 235×185×120mm
Installation methods Wall mounting

1

Model No.

CS6530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

Factory making Soil Ph Tester - Online Dissolved Ozone Meter T6558 – Chunye detail pictures

Factory making Soil Ph Tester - Online Dissolved Ozone Meter T6558 – Chunye detail pictures

Factory making Soil Ph Tester - Online Dissolved Ozone Meter T6558 – Chunye detail pictures


Related Product Guide:

Sticking for the belief of "Creating items of top of the range and creating buddies with people today from all over the world", we normally put the interest of shoppers in the first place for Factory making Soil Ph Tester - Online Dissolved Ozone Meter T6558 – Chunye , The product will supply to all over the world, such as: Jordan, Algeria, Slovakia, Furthermore, all of our products are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. If you are interested in any of our products, please don't hesitate to contact us. We will do our best to meet your needs.
  • We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Diego from Auckland - 2018.11.04 10:32
    This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Mildred from Zurich - 2017.01.28 18:53
    Write your message here and send it to us