Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Dissolved Ozone Meter T4058 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With dependable high quality approach, great reputation and excellent customer support, the series of products and solutions produced by our firm are exported to lots of countries and regions for Online Turbidimeter, Fluoride ion Selective Electrode, Garden Ph Tester, We warmly welcome all standpoint inquiries from home and abroad to cooperate with us, and anticipate your correspondence.
Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Dissolved Ozone Meter T4058 – Chunye Detail:

Function

Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control chlorine dioxide and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 98*98*120mm meter size, 92.5*92.5mm hole size, 3.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

4.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

5.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

1

Technical specifications

Measurement range 0.005~20mg/L;0.005~20.00ppm
Measurement theory Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic error ±1%F.S
Temperature 0~50.0°C
Temperature resolution 0.1°C
Temperature accuracy ±0.3°C
Temperature compensation 0~60.0°C
Temperature compensation Manual or automatic
Electrode residual signal <1‰
Response time 25°C<60S; 35°C<30S (To attain 90%)
Stability At constant pressure and temperature, the weekly drift<2%F•S;
Current output Two:4~20mA,20~4mA,0~20mA(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control set-points Two:3A 250VAC,3A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference except the geomagnetic field.
Working temperature -10~60°C
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.6kg
Dimensions 98×98×120mm
Installation opening size 92.5×92.5mm
Installation methods Panel, wall mounting or pipeline

1

Model No.

CS6530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Dissolved Ozone Meter T4058 – Chunye detail pictures

Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Dissolved Ozone Meter T4058 – Chunye detail pictures

Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Dissolved Ozone Meter T4058 – Chunye detail pictures


Related Product Guide:

The really abundant projects administration experiences and just one to one particular provider model make the substantial importance of organization communication and our easy understanding of your expectations for Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Dissolved Ozone Meter T4058 – Chunye , The product will supply to all over the world, such as: Seychelles, Marseille, Korea, Each year, many of our customers would visit our company and achieve great business advancements working with us. We sincerely welcome you to visit us at any time and together we will prevail to a greater success in the hair industry.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Judy from Kazakhstan - 2017.12.31 14:53
    Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Stephanie from Sydney - 2017.09.26 12:12
    Write your message here and send it to us