Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for Residual Chlorine And Free Chlorine, Ammonia Nitrogen Tester Meter, Wastewater Monitoring System, We can customize the products according to your requirements and we can pack it for you when you order.
Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Turbidity Meter T6570 – Chunye Detail:

Turbidity
Function

The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.

Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and 

Typical Use

The online turbidity meter is an online analytical instrument designed to measure the turbidity of water from waterworks, municipal pipeline network, industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc. especially in the treatment of municipal sewage or industrial wastewater.

Whether evaluating activated sludge and the entire biological treatment process, analyzing wastewater discharged after purification treatment, or detecting sludge concentration at different stages, the sludge concentration meter can give continuous and accurate measurement results.

Mains Supply

85~265VAC±10%,50±1Hz,power consumption ≤3W;
9~36VDC,power consumption:≤3W;

Measuring Range

Turbidity: 0~9999NTU

Features

1.Large display, standard 485 communication, with online and offline alarm, 235*185*120mm meter size, 7.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Real-time online recording of MLSS/SS, temperature data and curves, compatible with all water quality meters of our company.

4.0-20NTU, 0-400NTU, 0-4000NTU, a variety of measuring ranges are available, suitable for different working conditions, the measurement accuracy is less than ±5% of the measured value.

5.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.

6.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

7.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

111

Technical specifications

Measurement range 0-9999NTU
Measurement unit NTU, mg/L
Resolution 0.001; 0.01; 0.1; 1
Basic error ±1%F.S
Temperature -10~150℃
Temperature Resolution 0.1℃
Temperature Basic error ±0.3℃
Current outputs Two 4~20mA,20~4mA,0~20mA
Signal output RS485 MODBUS RTU
Other functions Data record &Curve display
Relay control contacts 3 Group: 5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions There is no strong magnetic interference besides the earth
Working temperature -10~60℃
Relative humidity ≤90%
Waterproof rating IP65
Weight 1.5 kg
Dimensions 235×185×120mm
Installation Wall mounted

Product detail pictures:

Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Turbidity Meter T6570 – Chunye detail pictures

Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Turbidity Meter T6570 – Chunye detail pictures

Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Turbidity Meter T6570 – Chunye detail pictures


Related Product Guide:

Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Factory Price For Free Chlorine Sensor Residual Chlorine RS485 - Online Turbidity Meter T6570 – Chunye , The product will supply to all over the world, such as: Jamaica, Romania, Orlando, Our production have been exported to more than 30 countries and regions as first hand source with lowest price. We sincerely welcome customers from both at home and abroad to come to negotiate business with us.
  • This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Christina from Sevilla - 2018.02.04 14:13
    Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Ingrid from Sudan - 2018.06.19 10:42
    Write your message here and send it to us