Factory Price Water Consumption Monitoring System - Online Membrane Residual Chlorine Meter T4055 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Usually customer-oriented, and it's our ultimate focus on to be not only by far the most reliable, trustable and honest provider, but also the partner for our customers for Ph Tester, NO230 Tester Meter, Chemical Oxygen Demand COD Sensor RS485, Be sure to never wait to get in touch with us for anyone who is interested within our solutions. We firmly believe that our products and solutions will make you happy.
Factory Price Water Consumption Monitoring System - Online Membrane Residual Chlorine Meter T4055 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine, pH and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm; 0~20mg/L;
pH: -2~16pH;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 98*98*130mm meter size, 92.5*92.5mm hole size,  3.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

4.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

5.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

a2

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Membrane
Resolution 0.001mg/L ; 0.001ppm
Basic error

±1%F.S

։

Measurement range -2 16.00pH
Measurement unit pH
Resolution 0.001pH
Basic error ±0.01pH։ ˫
Temperature -10 150.0 ( Based on sensor)˫
Temperature Resolution 0.1˫
Temperature Basic error ±0.3։
Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record
Three relay control contacts 2 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.։ ˫
Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.6kg
Dimensions 98×98×130mm
Installation opening size 92.5×92.5mm
Installation methods Panel & wall mounted or pipeline

b1

Model No.

CS5763

Measurement method

Membrane

Housing material

POM+316L Stainless

Waterproof grade

IP68

Measurement range

0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

NTC10K

Temperature range

0-50℃

Calibration

Chlorine-free water, water sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

NPT3/4’’

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

Factory Price Water Consumption Monitoring System - Online Membrane Residual Chlorine Meter T4055 – Chunye detail pictures

Factory Price Water Consumption Monitoring System - Online Membrane Residual Chlorine Meter T4055 – Chunye detail pictures

Factory Price Water Consumption Monitoring System - Online Membrane Residual Chlorine Meter T4055 – Chunye detail pictures


Related Product Guide:

That has a sound business credit history, outstanding after-sales service and modern producing facilities, we have earned an superb popularity amid our buyers across the planet for Factory Price Water Consumption Monitoring System - Online Membrane Residual Chlorine Meter T4055 – Chunye , The product will supply to all over the world, such as: Panama, Lesotho, Danish, We pay high attention to customer service, and cherish every customer. We've maintained a strong reputation in the industry for many years. We are honest and work on building a long-term relationship with our customers.
  • The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Rebecca from Madagascar - 2017.06.16 18:23
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Mary from Singapore - 2018.12.05 13:53
    Write your message here and send it to us