1.Product Overview:
The analyzer can automatically and continuously work unattended for a long time according to the site setting, and is widely used in industrial pollution source discharge wastewater, industrial process wastewater, industrial sewage treatment plant sewage, municipal sewage treatment plant sewage and other occasions. According to the complexity of the field test conditions, the corresponding pretreatment system can be selected to ensure the reliability of the test process and the accuracy of the test results, and fully meet the field needs of different occasions.
2.Product Principle:
This product is determined by dibenzoyl dihydrazine spectrophotometric colorimetric method. After mixing the water sample and the regulator, hexavalent chromium reacts with the indicator to form a colored complex in the acidic environment and the presence of the indicator. The analyzer detects the color change and converts this change into hexavalent chromium value output. The amount of colored complex produced is equivalent to the amount of hexavalent chromium.
This method is suitable for waste water with hexavalent chromium in the range of 0~30mg/L.
3.Technical Parameters:
|
No. |
Name |
Technical Specifications |
|
1 |
Application Range |
This method is suitable for wastewater with hexavalent chromium in the range of 0~30mg/L.
|
|
2 |
Test Methods |
Dibenzoyl dihydrazine spectrophotometric colorimetry |
|
3 |
Measuring range |
0~30mg/L |
|
4 |
Lower limit of Detection |
0.01 |
|
5 |
Resolution |
0.001 |
|
6 |
Accuracy |
±10% or ±0.05mg/L(Take the bigger value) |
|
7 |
Repeatability |
10% or 0.05mg/L(Take the larger value) |
|
8 |
Zero Drift |
±0.05mg/L |
|
9 |
Span Drift |
±10% |
|
10 |
Measurement cycle |
Minimum 20 minutes. According to the actual water sample, the digestion time can be set from 5 to120 minutes. |
|
11 |
Sampling period |
Time interval (adjustable), integral hour or trigger measurement mode can be set. |
|
12 |
Calibration cycle |
Automatic calibration (1-99 days adjustable), according to actual water samples, manual calibration can be set. |
|
13 |
Maintenance cycle |
Maintenance interval is more than one month, about 30 minutes each time. |
|
14 |
Human-machine operation |
Touch screen display and instruction input. |
|
15 |
Self checking protection |
Working status is self-diagnostic, abnormal or power failure will not lose data. Automatically eliminates residual reactants and resumes work after abnormal reset or power failure. |
|
16 |
Data storage |
No less than half a year data storage |
|
17 |
Input interface |
Switch quantity |
|
18 |
Output interface |
Two RS485 digital output, One 4-20mA analog output |
|
19 |
Working Conditions |
Working indoors; temperature 5-28℃; relative humidity≤90% (no condensation,no dew) |
|
20 |
Power Supply Consumption |
AC230±10%V, 50~60Hz, 5A |
|
21 |
Dimensions |
355×400×600(mm) |