Our mission should be to turn out to be an innovative supplier of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and repair capabilities for Eco Ph Tester, Plant Ph Tester, H2 Tester Meter, We have professional products knowledge and rich experience on manufacturing. We always believe your success is our business!
Hot New Products Dissolved Oxygen Sensor - Online Conductivity / Resistivity / TDS / Salinity Meter T4030 – Chunye Detail:

T4030-1
T4030-A
T4030-B
Function
Industrial online conductivity meter is a microprocessor-based water quality online monitoring control instrument, the salinometer measures and supervises the salinity (salt content) by conductivity measurement in fresh water. The measured value is displayed as ppm and by comparing the measured value to a user defined alarm set point value, relay outputs are available to indicate if salinity is above or below the alarm set point value.
Typical Use
This instrument is widely used in power plants, petrochemical industry, metallurgical electronics, mining industry, paper industry, medicine, food and beverage, water treatment, modern agricultural planting and other industries. It is suitable for softening water, raw water, steam condensate water, seawater distillation and deionized water, etc. It can continuously monitor and control the conductivity, resistivity, TDS, salinity and temperature of aqueous solutions.
Mains Supply
85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;
Measuring Range
Conductivity: 0~500ms/cm;
Resistivity: 0~18.25MΩ/cm; TDS:0~250g/L;
Salinity: 0~700ppt;
Customizable measuring range, displayed in ppm unit.

Online Conductivity / Resistivity /TDS / Salinity Meter T4030

Measuring Range

1.Large display, standard 485 communication, with online and offline alarm, 98*98*130mm meter size, 92.5*92.5mm hole size,3.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.It can be matched with our high-quality stainless steel, PBT quadrupole conductivity electrode, and the measurement range covers 0.00us/cm-500ms/cm to meet your measurement requirements for various working conditions.

4.Built-in conductivity/resistivity/salinity/total dissolved solids measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available tomeet various industrial site installation requirements.

Protection
Salinometer for panel mounting is IP65 from the front. Salinometer in wall mounting box is IP65.
Electrical connections
Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.
Instrument installation method
11
Technical specifications

Conductivity 0~500mS/cm
Resolution 0.1us/cm;0.01ms/cm
Intrinsic error ±0.5%F.S
Resistivity 0~18.25MΩ/cm
Resolution 0.01KΩ/cm;0.01MΩ/cm
TDS 0~9999mg/L; 0~250g/L
Resolution 0.01mg/L;0.01g/L
Salinity 0~700ppt
Resolution 0.01ppm;0.01ppt
Temperature -10~150℃
Resolution ±0.3℃
Temperature compensation Automatic or manual
Current output 2 Rd 4~20mA
Communication output RS 485 Modbus RTU
Other function Data recording, curve display, data uploading
Relay control contact 2 Groups: 3A 250VAC,3A 30VDC
Optional power supply 85~265VAC,9~36VDC, Power: ≤3W
The work environment In addition to the earth’s magnetic field around no strong

magnetic field interference

The environmental temperature -10~60℃
Relative humidity No more than 90%
Protection grade IP65
The instrument weight 0.6kg
Instrument dimensions 98*98*130mm
Mounting hole dimensions 92.5*92.5mm
Installation Embedded, wall – mounted, pipeline

Product detail pictures:

Hot New Products Dissolved Oxygen Sensor - Online Conductivity / Resistivity / TDS / Salinity Meter T4030 – Chunye detail pictures

Hot New Products Dissolved Oxygen Sensor - Online Conductivity / Resistivity / TDS / Salinity Meter T4030 – Chunye detail pictures

Hot New Products Dissolved Oxygen Sensor - Online Conductivity / Resistivity / TDS / Salinity Meter T4030 – Chunye detail pictures

Hot New Products Dissolved Oxygen Sensor - Online Conductivity / Resistivity / TDS / Salinity Meter T4030 – Chunye detail pictures


Related Product Guide:

"Control the standard by the details, show the power by quality". Our business has strived to establish a highly efficient and stable team staff and explored an effective good quality regulate course of action for Hot New Products Dissolved Oxygen Sensor - Online Conductivity / Resistivity / TDS / Salinity Meter T4030 – Chunye , The product will supply to all over the world, such as: Tunisia, Oman, Poland, We taking advantage of experience workmanship, scientific administration and advanced equipment, ensure the product quality of production, we not only win the customers' faith, but also build up our brand. Today, our team is committed to innovation, and enlightenment and fusion with constant practice and outstanding wisdom and philosophy, we cater to the market demand for high-end products, to do professional products.
  • Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Moira from Greenland - 2018.05.15 10:52
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Arthur from panama - 2017.04.18 16:45
    Write your message here and send it to us