We persistently execute our spirit of ''Innovation bringing growth, Highly-quality making sure subsistence, Administration marketing reward, Credit history attracting clients for Water Treatment Process Monitoring System, Ph Master Tester, Carbon Dioxide Meter Tester, Trust us and you will gain more. Please feel free to contact us for more information, we assure you of our best attention at all times.
Hot sale Electrical Conductivity Sensor - Online Membrane Residual Chlorine Meter T6055 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine, pH and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm;
pH: -2~16pH;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

aaa

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Membrane
Resolution 0.001mg/L ; 0.001ppm
Basic error

±1%F.S

։

Measurement range -2 16.00pH
Measurement unit pH
Resolution 0.001pH
Basic error ±0.01pH։ ˫
Temperature -10 150.0 ( Based on sensor)˫
Temperature Resolution 0.1˫
Temperature Basic error ±0.3։
Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.։ ˫
Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

b1

Model No.

CS5763

Measurement method

Membrane

Housing material

POM+316L Stainless

Waterproof grade

IP68

Measurement range

0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

NTC10K

Temperature range

0-50℃

Calibration

Chlorine-free water, water sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

NPT3/4’’

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

Hot sale Electrical Conductivity Sensor - Online Membrane Residual Chlorine Meter T6055 – Chunye detail pictures

Hot sale Electrical Conductivity Sensor - Online Membrane Residual Chlorine Meter T6055 – Chunye detail pictures

Hot sale Electrical Conductivity Sensor - Online Membrane Residual Chlorine Meter T6055 – Chunye detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Hot sale Electrical Conductivity Sensor - Online Membrane Residual Chlorine Meter T6055 – Chunye , The product will supply to all over the world, such as: Iceland, Lyon, moldova, Immediate and expert after-sale service supplied by our consultant group has happy our buyers. Comprehensive Info and parameters from the merchandise will probably be sent to you for any comprehensive acknowledge. Free samples may be delivered and company check out to our corporation. n Morocco for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Victor from Amsterdam - 2017.11.20 15:58
    We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Norma from Kuala Lumpur - 2017.11.12 12:31
    Write your message here and send it to us