Manufacturer of Online Chlorine Dioxide Sensor for Waste water - Online Ultrasonic Sludge Interface Meter T6080 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for Ammonia Nitrogen Tester Meter, Polarographic Dissolved Oxygen Sensor, Conductivity Meter Tester, Welcome friends from all over the world come to visit, guide and negotiate.
Manufacturer of Online Chlorine Dioxide Sensor for Waste water - Online Ultrasonic Sludge Interface Meter T6080 – Chunye Detail:

T6080
6000-A
6000-B
Function

The Ultrasound Sludge Interface sensor can be used to continuously and accurately determine the Liquid Level. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.

Typical Use

The online Ultrasound Sludge Interface Meter is an online analytical instrument designed to measure the Sludge Interface of water from waterworks, municipal pipeline network, industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc. especially in the treatment of municipal sewage or industrial wastewater. Whether evaluating activated sludge and the entire biological treatment process, analyzing wastewater discharged after purification treatment, or detecting sludge concentration at different stages, the Sludge Interface meter can give continuous and accurate measurement results.

Mains Supply

85~265VAC±10%,50±1Hz,power consumption ≤3W; 

9~36VDC,power consumption:≤3W;

Measuring Range

Liquid Level: 0~5m, 0~10m, 0~20m

Online Ultrasonic Sludge Interface Meter T6080

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138 hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Real-time online recording of Sludge Interface, temperature data and curves, compatible with all water quality meters of our company.

4.0-5m, 0-10m, a variety of measuring ranges are available, suitable for different working conditions, the measurement accuracy is less than ±5% of the measured value.

5.The new choke inductance of the power board can effectively reduce the influence of electromagnetic interference, and the data is more stable.

6.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

7.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method
1
Technical specifications

Measurement range 0~5m, 0~10m (Optional)
Measurement unit m
Resolution 0.01m
Basic error ±1%F.S
Temperature 0~50
Temperature Resolution 0.1
Temperature Basic error ±0.3
Current outputs Two 4~20mA,20~4mA,0~20mA
Signal output RS485 MODBUS RTU
Other functions Data record &Curve display
Three relay control contacts 5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10~60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

1

Model NO.

CS6080D

Power/Signal Output

9~36VDC/RS485 MODBUS RTU

Measure methods

Ultrasonic wave

Housing material

304/PTFE

Waterproof grade

IP68

Measurement range

0-5/0-10m (Optional)

Measuring blind zone

<20 cm

Accuracy

<0.3%

Temperature range

0-80℃

Cable length

Standard 10m cable
                 Application Sewage, industrial water, river

1

When selecting the sensor installation location, the following criteria should be followed:

●Keep the sensor perpendicular to the mud surface and the bottom of the pool.
●There should be no obstacles in the transmitting range directly below the probe to avoid the ultrasonic signal being blocked and reflected by obstacles.
●The probe should be installed away from gas foam and active floating solids caused by sudden flow rate to ensure accurate and stable measurement.
●The probe should be installed away from the inlet and outlet.
●The sensor probe should be completely submerged in water. If the wall is vertical up and down and the surface is flat, determine the distance from the wall according to the table below.
●If the pool wall is uneven, or there are supports, pipes and other objects, it is necessary to increase the distance from the pool wall, in order to avoid the interference caused by the above objects to the measurement.


Product detail pictures:

Manufacturer of Online Chlorine Dioxide Sensor for Waste water - Online Ultrasonic Sludge Interface Meter T6080 – Chunye detail pictures

Manufacturer of Online Chlorine Dioxide Sensor for Waste water - Online Ultrasonic Sludge Interface Meter T6080 – Chunye detail pictures

Manufacturer of Online Chlorine Dioxide Sensor for Waste water - Online Ultrasonic Sludge Interface Meter T6080 – Chunye detail pictures


Related Product Guide:

Our mission is usually to turn into an innovative provider of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and service capabilities for Manufacturer of Online Chlorine Dioxide Sensor for Waste water - Online Ultrasonic Sludge Interface Meter T6080 – Chunye , The product will supply to all over the world, such as: United Kingdom, Cyprus, Bangalore, To have much more enterprise. ompanions, we've got updated the item list and seek for optimistic co-operation. Our web-site shows the latest and complete information and facts about our goods list and company. For further acknowledge, our consultant service group in Bulgaria will reply to all of the inquiries and complications immediately. They're going to make their finest effort to meet buyers need. Also we support the delivery of absolutely free samples. Business visits to our business in Bulgaria and factory are generally welcome for a win-win negotiation. Hope to expertise a happy company co-operation perform with you.
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Candance from Guatemala - 2018.08.12 12:27
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Gwendolyn from South Korea - 2018.12.25 12:43
    Write your message here and send it to us