We attempt for excellence, provider the customers", hopes to be the most beneficial cooperation team and dominator enterprise for staff, suppliers and shoppers, realizes value share and continuous advertising for Electronic Soil Ph Tester, Complex Environment ORP Electrode, Water Quality Monitoring Sites, We have been sincerely looking forward to developing very good cooperative relationships with buyers from at home and abroad for creating a vibrant foreseeable future together.
OEM Manufacturer Conductivity Meter Manual - Online Dissolved Ozone Meter T4058 – Chunye Detail:

Function

Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control chlorine dioxide and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 98*98*120mm meter size, 92.5*92.5mm hole size, 3.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

4.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

5.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

1

Technical specifications

Measurement range 0.005~20mg/L;0.005~20.00ppm
Measurement theory Potentiometric method
Resolution 0.001mg/L;0.001ppm
Basic error ±1%F.S
Temperature 0~50.0°C
Temperature resolution 0.1°C
Temperature accuracy ±0.3°C
Temperature compensation 0~60.0°C
Temperature compensation Manual or automatic
Electrode residual signal <1‰
Response time 25°C<60S; 35°C<30S (To attain 90%)
Stability At constant pressure and temperature, the weekly drift<2%F•S;
Current output Two:4~20mA,20~4mA,0~20mA(load resistance<750Ω)
Communication output RS485 MODBUS RTU
Relay control set-points Two:3A 250VAC,3A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference except the geomagnetic field.
Working temperature -10~60°C
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.6kg
Dimensions 98×98×120mm
Installation opening size 92.5×92.5mm
Installation methods Panel, wall mounting or pipeline

1

Model No.

CS6530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

Product detail pictures:

OEM Manufacturer Conductivity Meter Manual - Online Dissolved Ozone Meter T4058 – Chunye detail pictures

OEM Manufacturer Conductivity Meter Manual - Online Dissolved Ozone Meter T4058 – Chunye detail pictures

OEM Manufacturer Conductivity Meter Manual - Online Dissolved Ozone Meter T4058 – Chunye detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" is the persistent conception of our company for the long-term to develop together with customers for mutual reciprocity and mutual benefit for OEM Manufacturer Conductivity Meter Manual - Online Dissolved Ozone Meter T4058 – Chunye , The product will supply to all over the world, such as: Morocco, Ukraine, Czech, Certainly, competitive price, suitable package and timely delivery will be assured as per customers' demands. We sincerely hope to build business relationship with you on the basis of mutual benefit and profit in the very near future. Warmly welcome to contact us and become our direct cooperators.
  • This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Polly from South Korea - 2017.08.18 11:04
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Bess from Kenya - 2018.10.01 14:14
    Write your message here and send it to us