Product Description:
Manganese is one of the common heavy metal
elements in water bodies, and its excessive
concentration can severely impact aquatic
environments and ecosystems. Excessive
manganese not only darkens water color and
produces unpleasant odors but also affects the
growth and reproduction of aquatic organisms.
It can even transmit through the food chain,
posing a potential threat to human health. Therefore, real-time and accurate monitoring of total manganese content in water quality is crucial.
Product Principle:
This product employs spectrophotometric measurement. After mixing the water sample with the buffer agent, manganese is converted into its respective higher-valent ions in the presence of a strong oxidizing agent. In the presence of the buffer solution and indicator, the higher-valent ions react with the indicator to form a colored complex. The analyzer detects this color change and converts it into a manganese value output. The amount of colored complex formed corresponds to the manganese content.
Technical Specifications:
|
SN |
Specification Name |
Technical Specifications |
|
1 |
Test Method |
High Iodic Acid Spectrophotometric Method |
|
2 |
Measurement Range |
0–30 mg/L (segmented measurement, expandable) |
|
3 |
Detection limit |
≤0.02 |
|
4 |
Resolution |
0.001 |
|
5 |
Accuracy |
±10% |
|
6 |
Repeatability |
≤5% |
|
7 |
Zero drift |
±5% |
|
8 |
Range drift |
±5% |
|
9 |
Measurement Cycle |
Less than 30 minutes; digestion time can be set. |
|
10 |
Sampling Cycle |
Time interval (adjustable), hourly, or trigger measurement mode, configurable |
|
11 |
Calibration Cycle |
Auto-calibration (adjustable from 1 to 99 days), manual calibration can be set based on actual water samples. |
|
12 |
Maintenance Cycle |
Maintenance intervals exceed one month, with each session lasting approximately 5 minutes. |
|
13 |
Human-Machine Operation |
Touchscreen Display and Command Input |
|
14 |
Self-Diagnostic Protection |
The instrument performs self-diagnostics during operation and retains data after abnormalities or power loss. Following abnormal resets or power restoration, it automatically purges residual reagents and resumes normal operation. |
|
15 |
Data Storage |
5-Year Data Storage |
|
16 |
One-Button Maintenance |
Automatically drains old reagents and cleans tubing; replaces new reagents, performs automatic calibration and verification; optional automatic cleaning of digestion cells and metering tubes with cleaning solution. |
|
17 |
Quick Debugging |
Achieve unattended, uninterrupted operation with automatic generation of debugging reports, greatly enhancing user convenience and reducing labor costs. |
|
18 |
Input Interface |
switching value |
|
19 |
Output Interface |
1 channel RS232 output, 1 channel RS485 output, 1 channel 4–20 mA output |
|
20 |
Operating Environment |
Indoor operation, recommended temperature range: 5–28℃, humidity ≤90% (non-condensing) |
|
21 |
Power Supply |
AC220±10%V |
|
22 |
Frequency |
50±0.5Hz |
|
23 |
Power |
≤150 W (excluding sampling pump) |
|
24 |
Dimensions |
1,470 mm (H) × 500 mm (W) × 400 mm (D) |