Online Exporter Water Ph Monitoring System - Online Residual Chlorine Meter T6550 – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Toroidal Conductivity Sensor, Wireless Conductivity Sensor, Electrical Conductivity Sensor, Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software development are our distinguishing feature.
Online Exporter Water Ph Monitoring System - Online Residual Chlorine Meter T6550 – Chunye Detail:

Function

Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control residual chlorine and  temperature  value  in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Residual Chlorine: 0~20ppm; 0~20mg/L;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 235*185*120mm meter size, 7.0 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The residual chlorine measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

bbb

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S
Temperature -10 150.0 ˫( Based on sensor) 
Temperature Resolution 0.1˫
Temperature Basic error ±0.3˫
Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.
Working temperature -10 60
Working temperature 10։60˫
Relative humidity ≤90%
Waterproof rating IP65
Weight 1.5kg
Dimensions 235×185×120mm
Installation methods Wall mounted

1

Model No.

CS5530

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

Online Exporter Water Ph Monitoring System - Online Residual Chlorine Meter T6550 – Chunye detail pictures

Online Exporter Water Ph Monitoring System - Online Residual Chlorine Meter T6550 – Chunye detail pictures

Online Exporter Water Ph Monitoring System - Online Residual Chlorine Meter T6550 – Chunye detail pictures


Related Product Guide:

We've our have sales staff, style and design staff, technical crew, QC team and package workforce. We've strict excellent control procedures for each system. Also, all of our workers are experienced in printing field for Online Exporter Water Ph Monitoring System - Online Residual Chlorine Meter T6550 – Chunye , The product will supply to all over the world, such as: Bolivia, Cambodia, Swaziland, With a wide range, good quality, reasonable prices and stylish designs, our products are extensively used in beauty and other industries. Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs.
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Julia from Adelaide - 2018.06.28 19:27
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Freda from Russia - 2017.11.12 12:31
    Write your message here and send it to us