1.Product Overview:
This product adopts spectrophotometric measurement. Under certain acidity conditions, the ferrous ions in the sample react with the indicator to generate a red complex. The analyzer detects the color change and converts it into iron values. The amount of colored complex generated is proportional to the iron content.
2.Product Principle:
2.1 Instrument Features:
Ø Uses photometric medicine addition, enables precise metering;
Ø Cold light source spectral measurement, extends light source life;
Ø Automatically adjusts light source intensity, maintains measurement accuracy after light source decay;
Ø Automatically controls reaction temperature, constant temperature measurement and calibration;
Ø Large capacity memory, saves 5 years of measurement data;
Ø 7-inch touch color LCD, more intuitive operation and display;
Ø Single channel of isolated current output, configurable to any channel, any range or PID;
Ø Single channel of relay output, can be configured for over-limit alarm, no-sample alarm or system failure alarm;
Ø RS485 interface, enables remote data monitoring;
Ø Query curves and measurement alarms for any time period.
3.Technical Parameters:
|
No. |
Name |
Technical Specifications |
|
1 |
Application Range |
This method is suitable for wastewater with total iron in the range of 0~5mg/L.
|
|
2 |
Test Methods |
Spectrophotometric |
|
3 |
Measuring range |
0~5mg/L |
|
4 |
Lower limit of Detection |
0.02 |
|
5 |
Resolution |
0.001 |
|
6 |
Accuracy |
±10% or ±0.02mg/L(Take the bigger value) |
|
7 |
Repeatability |
10% or 0.02mg/L(Take the larger value) |
|
8 |
Zero Drift |
±0.02mg/L |
|
9 |
Span Drift |
±10% |
|
10 |
Measurement cycle |
Minimum 20 minutes. According to the actual water sample, the digestion time can be set from 5 to120 minutes. |
|
11 |
Sampling period |
Time interval (adjustable), integral hour or trigger measurement mode can be set. |
|
12 |
Calibration cycle |
Automatic calibration (1-99 days adjustable), according to actual water samples, manual calibration can be set. |
|
13 |
Maintenance cycle |
Maintenance interval is more than one month, about 30 minutes each time. |
|
14 |
Human-machine operation |
Touch screen display and instruction input. |
|
15 |
Self checking protection |
Working status is self-diagnostic, abnormal or power failure will not lose data. Automatically eliminates residual reactants and resumes work after abnormal reset or power failure. |
|
16 |
Data storage |
No less than half a year data storage |
|
17 |
Input interface |
Switch quantity |
|
18 |
Output interface |
Two RS485 digital output, One 4-20mA analog output |
|
19 |
Working Conditions |
Working indoors; temperature 5-28℃; relative humidity≤90% (no condensation,no dew) |
|
20 |
Power Supply Consumption |
AC230±10%V, 50~60Hz, 5A |
|
21 |
Dimensions |
355×400×600(mm) |