  • CS1788 Plastic Housing pH Sensor

    CS1788 Plastic Housing pH Sensor

    Designed for pure water, low Ion concentration environment.
  • CS1588 Glass Housing pH Sensor

    CS1588 Glass Housing pH Sensor

    Designed for pure water, low Ion concentration environment.
  • CS1745 Plastic Housing pH Sensor

    CS1745 Plastic Housing pH Sensor

    Designed for High temperature and biological fermentation process.
    CS1745 pH electrode adopts the most advanced solid dielectric in the world and large-area PTFE liquid junction. Not easy to block, easy to maintain. The long-distance reference diffusion path greatly prolongs the service life of the electrode in harsh environments. With built-in temperature sensor (Pt100, Pt1000, etc. can be selected according to user requirements) and wide temperature range, it can be used in explosion-proof areas.
  • CS1737 Plastic Housing pH Sensor

    CS1737 Plastic Housing pH Sensor

    Designed for Hydrofluoric acid environment.
    HF concentration>1000ppm
    The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
  • CS1753 Plastic Housing pH Sensor

    CS1753 Plastic Housing pH Sensor

    Designed for strong acid, strong base, waste water and chemical process.
  • Online pH/ORP Analyzer Meter for Water Treatment with CE T6500

    Online pH/ORP Analyzer Meter for Water Treatment with CE T6500

    Industrial on-line PH/ORP meter is an on-line water quality monitoring and control instrument with microprocessor.PH electrodes or ORP electrodes of different types are widely used in power plant, petrochemical industry, metallurgical electronics, mining industry, paper industry, biological fermentation engineering, medicine, food and beverage, environmental water treatment, aquaculture, modern agriculture, etc.The pH (acid, alkalinity) value, ORP (oxidation, reduction potential) value and temperature value of aqueous solution were continuously monitored and controlled.
  • CS1500 Glass Housing pH Sensor High Quality for Labaratory

    CS1500 Glass Housing pH Sensor High Quality for Labaratory

    Designed for common water quality.
    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage.
    The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
    High-strength glass bulb design, the glass appearance is stronger.
    The electrode adopts low noise cable, the signal output is farther and more stable
    Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in common water quality environment media.
  • CS1501 Glass Housing pH Sensor High Quality Water Treatment Combination

    CS1501 Glass Housing pH Sensor High Quality Water Treatment Combination

    Designed for common water quality.
    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage.
    The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
    High-strength glass bulb design, the glass appearance is stronger.
    The electrode adopts low noise cable, the signal output is farther and more stable
    Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in common water quality environment media.
  • CS1700 Electrode Economy Digital Plastic Housing pH Sensor

    CS1700 Electrode Economy Digital Plastic Housing pH Sensor

    Designed for common water quality.
    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage.
    The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
    High-strength glass bulb design, the glass appearance is stronger.
    The electrode adopts low noise cable, the signal output is farther and more stable
    Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in common water quality environment media.
  • CS1701pH Sensor Electrode Economy Digital RS485 4~20mA output

    CS1701pH Sensor Electrode Economy Digital RS485 4~20mA output

    Applied for General Industrial Process
    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage.
    The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
    High-strength glass bulb design, the glass appearance is stronger.
    The electrode adopts low noise cable, the signal output is farther and more stable
    Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in common water quality environment media.
  • CS1778 pH Sensor Double junction long lifetime Plastic Housing

    CS1778 pH Sensor Double junction long lifetime Plastic Housing

    The working conditions of the desulfurization industry are more complicated. The common ones include liquid alkali desulfurization (adding NaOH solution in the circulating liquid), flake alkali desulfurization (putting quicklime into the pool to generate lime slurry, which will also release more heat), double alkali method (quick lime And NaOH solution).
  • CS1545 pH Sensor Output Online Water Quality for Labaratory

    CS1545 pH Sensor Output Online Water Quality for Labaratory

    Designed for High temperature and biological fermentation process.
    CS1545 pH electrode adopts the most advanced solid dielectric in the world and large-area PTFE liquid junction. Not easy to block, easy to maintain. The long-distance reference diffusion path greatly prolongs the service life of the electrode in harsh environments. With built-in temperature sensor (Pt100, Pt1000, etc. can be selected according to user requirements) and wide temperature range, it can be used in explosion-proof areas.
  • CS1528 Glass Housing pH Sensor

    CS1528 Glass Housing pH Sensor

    Designed for Hydrofluoric acid environment.
    HF concentration < 1000ppm
    The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
  • CS1728 Plastic Housing pH Sensor

    CS1728 Plastic Housing pH Sensor

    Designed for Hydrofluoric acid environment.
    HF concentration < 1000ppm
    The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
  • CS1515 pH Sensor soil measurement

    CS1515 pH Sensor soil measurement

    Designed for moist soil measurement.
    The reference electrode system of CS1515 pH sensor is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.