Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

While using the "Client-Oriented" company philosophy, a demanding high-quality management method, innovative producing products and also a sturdy R&D workforce, we always deliver premium quality merchandise, superb solutions and aggressive selling prices for Water Consumption Monitoring System, Water Consumption Monitoring System, Conductivity Meter Tester, We always hold the philosophy of win-win, and build long-term cooperation relationship with customers from around the world.We believe that our growth base on customer's success, credit is our life.
Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye Detail:

The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.

The electrode body is made of POM, which is corrosion-resistant and more durable. The seawater version can be plated with titanium, which also performs well under strong corrosion.

IP68 waterproof design, can be used for input measurement. Real-time online recording of Turbidity/MLSS/SS, temperature data and curves, compatible with all water quality meters of our company.

0.001-20.00NTU-200.00NTU-400NTU, a variety of measuring ranges are available, suitable for different working conditions, the measurement accuracy is less than ±5% of the measured value.

Suspended Solids (Sludge concentration) monitoring of water from waterworks, water quality monitoring of municipal pipeline network; industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc.

This product is a circulating turbidity digital sensor, which can directly output RS485 signal.

The internal structure can effectively eliminate water bubbles and improve the measurement accuracy and stability.

When the outlet joint module is disassembled, the optical path lens and the inner wall of the flow groove can be cleaned, and the maintenance is more convenient.

The internal upgrade of the sensor can effectively prevent the internal circuit from dampness and dust accumulation, and avoid damage to the internal circuit.

The transmitted light adopts stable invisible near-monochromatic infrared light source, which avoids the interference of chroma in liquid and external visible light to sensor measurement.And built-in luminosity compensation, improve the measurement accuracy.

The use of quartz glass lens with high light transmittance in the optical path makes the transmission and reception of infrared light waves more stable.

Wide range, stable measurement, high precision, good reproducibility.

Without meter, the sensor can be set online through software, from the machine address and baud rate, online calibration, restore factory, RS485 output corresponding range, modify the range, proportional coefficient and incremental compensation Settings.

Turbidity monitoring of water from waterworks, water quality monitoring of municipal pipeline network; industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc.

Model No.

CS7800D

Power/Output

9~36VDC/RS485 MODBUS RTU

Measurement range

0.001-20.00NTU-200.00NTU-400NTU

Measurement mode

90°IR scattered light method

Weight

5.0kg

Housing material

POM+316 Stainless steel

Waterproof rating

IP68

Measurement accuracy

±5% or 0.5NTU,whichever is grater

Pressure resistance

≤0.3Mpa

Measuring temperature

0-45℃

Calibration

Standard liquid calibration, water sample calibration

Dimensions

400×300×170mm

Cable length

Standard 10m,can be extended to 100m

Installation

wall mounting ; matching with the filter tank;

Application

General applications, municipal pipeline network; industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc.

 


Product detail pictures:

Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye detail pictures

Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye detail pictures

Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye detail pictures

Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye detail pictures


Related Product Guide:

We've been proud with the significant shopper fulfillment and wide acceptance due to our persistent pursuit of top of the range both of those on solution and repair for Super Lowest Price Flow Through Conductivity Meter - CS7800D Online Turbidity Sensor – Chunye , The product will supply to all over the world, such as: Islamabad, Cancun, Singapore, Our products and solutions are sold to the Middle East, Southeast Asia, Africa, Europe, America and other regions, and are favorably appraised by clients. To benefit from our strong OEM/ODM capabilities and considerate services, be sure to contact us today. We will sincerely create and share success with all clients.
  • Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Nana from Israel - 2018.07.26 16:51
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Molly from Belize - 2017.11.29 11:09
    Write your message here and send it to us