We have our own product sales staff, style crew, technical group, QC staff and package staff. We now have strict high quality management procedures for each approach. Also, all of our workers are experienced in printing subject for Benchtop Digital Dissolved Oxygen Meter, Contacting Conductivity Sensor, Turbidity Meter, With the development of society and economy, our company will keep a tenet of "Focus on trust, quality the first", moreover, we expect to create a glorious future with every customer.
Super Purchasing for Simple Operation Handheld Conductivity TDS Salinity Meter - Online Chlorine Dioxide Meter T6053 – Chunye Detail:

Function

Online chlorine dioxide meter is a microprocessor-based water quality online monitoring control instrument.

Typical Use

This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. and other industrial processes. It continuous monitoring and control chlorine dioxide and temperature value in aqueous solution.

Mains Supply

85~265VAC±10%,50±1Hz, power ≤3W;
9~36VDC, power consumption≤3W;

Measuring Range

Chlorine dioxide: 0~20mg/L; 0~20ppm;
Temperature: 0~150℃.

Features

1.Large display, standard 485 communication, with online and offline alarm, 144*144*118mm meter size, 138*138mm hole size, 4.3 inch large screen display.

2.The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.

3.Historical curve: The chlorine dioxide measurement data can be stored automatically every 5 minutes, and the residual chlorine value can be stored continuously for a month. Provide “history curve” display and “fixed point” query function on the same screen.

4.Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards.

5.The design of the whole machine is waterproof and dustproof, and the back cover of the connection terminal is added to extend the service life in harsh environments.

6.Panel/wall/pipe installation, three options are available to meet various industrial site installation requirements.

Electrical connections

Electrical connection The connection between the instrument and the sensor: the power supply, output signal, relay alarm contact and the connection between the sensor and the instrument are all inside the instrument. The length of the lead wire for the fixed electrode is usually 5-10 meters, and the corresponding label or color on the sensor Insert the wire into the corresponding terminal inside the instrument and tighten it.

Instrument installation method

A1

Technical specifications

Measurement range 0.005~20.00mg/L ; 0.005~20.00ppm
Measurement unit Potentiometric method
Resolution 0.001mg/L ; 0.001ppm
Basic error ±1%F.S

։ ˫

Temperature -10 150.0 ( Based on sensor)

˫

Temperature Resolution 0.1

˫

Temperature Basic error ±0.3

։

Current output 2 groups: 4 20mA
Signal output RS485 Modbus RTU
Other functions Data record &Curve display
Three relay control contacts 3 groups:5A 250VAC,5A 30VDC
Optional power supply 85~265VAC,9~36VDC,power consumption≤3W
Working conditions No strong magnetic field interference around except the geomagnetic field.

։ ˫

Working temperature -10 60
Relative humidity ≤90%
Waterproof rating IP65
Weight 0.8kg
Dimensions 144×144×118mm
Installation opening size 138×138mm
Installation methods Panel & wall mounted or pipeline

1

Model No.

CS5560

Measurement method

Tri-electrode method

Measure material

Double liquid junction,annular liquid junction

Housing material/Dimensions

PP, Glass, 120mm*Φ12.7mm

Waterproof grade

IP68

Measurement range

0 – 5.000 mg/L, 0 – 20.00 mg/L

Accuracy

±0.05mg/L;

Pressure resistance

≤0.3Mpa

Temperature compensation

None or Customize NTC10K

Temperature range

0-50℃

Calibration

Sample calibration

Connection methods

4 core cable

Cable length

Standard 5m cable, can be extended to 100m

Installation thread

PG13.5

Application

Tap water, disinfectant fluid, etc.

 


Product detail pictures:

Super Purchasing for Simple Operation Handheld Conductivity TDS Salinity Meter - Online Chlorine Dioxide Meter T6053 – Chunye detail pictures

Super Purchasing for Simple Operation Handheld Conductivity TDS Salinity Meter - Online Chlorine Dioxide Meter T6053 – Chunye detail pictures

Super Purchasing for Simple Operation Handheld Conductivity TDS Salinity Meter - Online Chlorine Dioxide Meter T6053 – Chunye detail pictures


Related Product Guide:

Just about every member from our large efficiency income crew values customers' wants and enterprise communication for Super Purchasing for Simple Operation Handheld Conductivity TDS Salinity Meter - Online Chlorine Dioxide Meter T6053 – Chunye , The product will supply to all over the world, such as: Rotterdam, Costa rica, Stuttgart, Honest to every customers are our requested! First-class serve, best quality, best price and fastest delivery date is our advantage! Give every customers good serve is our tenet! This makes our company get the favour of customers and support! Welcome all over the world customers send us enquiry and looking forward your good co-operation !Please your inquiry for more details or request for dealership in selected regions.
  • Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Alma from Leicester - 2017.01.28 19:59
    We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Salome from Peru - 2018.05.13 17:00
    Write your message here and send it to us