T9015W Coliform Bacteria Water Quality Online Monitor

Short Description:

The Coliform Bacteria Water Quality Analyzer is an advanced automated instrument designed for the rapid, online detection and quantification of coliform bacteria, including Escherichia coli (E. coli), in water samples. As key fecal indicator organisms, coliform bacteria signal potential microbiological contamination from human or animal waste, directly impacting public health safety in drinking water, recreational waters, wastewater reuse systems, and food/beverage production. Traditional culture-based methods require 24-48 hours for results, creating critical response delays. This analyzer provides near real-time monitoring, enabling proactive risk management and immediate regulatory compliance validation.The analyzer offers significant operational advantages, including automated sample processing, reduced contamination risk, and configurable alarm thresholds. It features self-cleaning cycles, calibration verification, and comprehensive data logging. Supporting standard industrial communication protocols (e.g., Modbus, 4-20mA), it integrates seamlessly with plant control and SCADA systems for instant alerts and historical trend analysis.


Product Detail

Product Tags

Application Area

1.Surface water

2.Groundwater

3.Drinking water source

4.Emissions from livestock and poultry industry

5.Emissions from medical and pharmaceutical biological processes

6.Agricultural and urban wastewater

Instrument Features:

1.Using the fluorescent enzyme substrate method, the water sample has strong adaptability;

2.This device can be used for multiple purposes, and the indicators of "coliform bacteria, fecal coliform bacteria, and Escherichia coli" can be switched;

3.Non-disposable reagents are used, which is cost-effective and supports a maintenance-free period of 15 days. 、

4.It has negative quality control and can automatically determine whether it is in a sterile state;

5.It can customize the "reagent bag-packed solid powder automatic liquid mixing" function of reagent A;

6.It has an automatic water sample replacement function, reducing the influence of the previous water sample concentration and the residual is less than 0.001%;

7.It has a light source temperature control function to ensure the stability of the light source and reduce the interference of temperature on the light source;

8.Before and after the equipment starts measurement, it automatically cleans with clean water to ensure that the system is free from contamination;

9.Before and after the detection, the pipeline is sealed with liquid, and in combination with the sealed detection system, the interference from the environment on the system is eliminated;

Measurement Principle:

1. Measurement principle: Fluorescent enzyme substrate method;

2. Measurement range: 102cfu/L ~ 1012cfu/L (customizable from 10cfu/L to 1012/L);

3. Measurement period: 4 to 16 hours;

4. Sampling volume: 10ml;

5. Accuracy: ±10%;

6. Zero point calibration: The equipment automatically corrects the fluorescence baseline function, with a calibration range of 5%;

7. Detection limit: 10mL (customizable to 100mL);

8. Negative control: ≥1 day, can be set according to actual circumstances;

9. Dynamic flow path diagram: When the equipment is in measurement mode, it has the function of simulating actual measurement actions displayed in the flow chart: description of operation process steps, percentage of process progress display functions, etc.;

10. Key components use imported valve groups to form a unique flow path, ensuring the monitoring performance of the equipment;

11. Quantitative method: Use injection pump for quantification, with high measurement accuracy;

12. Quality control function: Includes instrument monitoring, precision, accuracy, correlation functions, mainly for the verification of instrument testing performance;

13. Pipeline disinfection: Before and after measurement, the equipment automatically disinfects with disinfectant to ensure no bacterial residue in the system;

14. The instrument internally uses a sterilization ultraviolet lamp to disinfect the sterile distilled water in the pipeline;

15. The instrument internally has real-time concentration, temperature, etc. trend analysis graphs;

16. Has power-on self-check, liquid level leak detection function;

17. Light source constant temperature: Has light source constant temperature function, temperature can be set; ensures the stability of the light source, reduces the interference of temperature on the light source;

18. Communication port: RS-232/485, RJ45 and (4-20) mA output;

19. Control signal: 2 switch output channels and 2 switch input channels;

20. Environmental requirements: Moisture-proof, dust-proof, temperature: 5 to 33℃;

21. Use 10-inch TFT, Cortex-A53, 4-core CPU as the core, high-performance embedded integrated touch screen;

22. Other aspects: Has the function of recording the instrument operation process log; can store at least one year of original data and operation logs; instrument abnormal alarm (including fault alarm, over-range alarm, over-limit alarm, reagent shortage alarm, etc.); power-off data is automatically saved; TFT true-color liquid crystal touch screen display and command input; abnormal reset and power-off recovery to normal working state after power-on; instrument status (such as measurement, idle, fault, maintenance, etc.) display function; the instrument has three-level management authority.