Digital Transmitter and Sensors Series

  • Digital RS485 Blue-green Algae Sensor for Water Quality Analysis  CS6401D

    Digital RS485 Blue-green Algae Sensor for Water Quality Analysis CS6401D

    CS6041D blue-green algae sensor uses the characteristic of cyanobacteria having absorption peak and emission peak in the spectrum to emit monochromatic light of a specific wavelength to the water. Cyanobacteria in the water absorb the energy of this monochromatic light and release monochromatic light of another wavelength. The light intensity emitted by cyanobacteria is proportional to the content of cyanobacteria in the water.Based on the fluorescence of the pigments to measurement the target parameters , it can be identified before the impact of algal bloom.No need for extraction or other treatment, rapid detection, to avoid the impact of shelving water samples;Digital sensor, strong anti-interference ability, long transmission distance;Standard digital signal output can be integrated and networked with other devices without controller.
  • Nitrate Ion Selective Electrod RS485 Output Water quality sensor ca2+ ion Electrode for Waste Water CS6720AD

    Nitrate Ion Selective Electrod RS485 Output Water quality sensor ca2+ ion Electrode for Waste Water CS6720AD

    CS6720AD digital nitrate ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions. The relationship between the potential of the electrode membrane and the ion content to be measured conforms to the Nernst formula. This type of electrode has the characteristics of good selectivity and short equilibrium time, making it the most commonly used indicator electrode for potential analysis
  • Industry Water Hardness Meter NH4 Ion Selective Electrode Sensor Probe RS485 CS6718AD

    Industry Water Hardness Meter NH4 Ion Selective Electrode Sensor Probe RS485 CS6718AD

    Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.The CS6718AD water hardness ion selective electrode is an effective method to measure the calcium ion content in the sample. Calcium ion selective electrodes are also often used in online instruments, such as industrial online calcium ion
    content monitoring. Calcium ion selective electrode has the advantages of simple measurement, fast and accurate response. It can be used with PH meter, ion meter and online calcium ion analyzer, and also used in electrolyte analyzer, and ion selective electrode detector of flow injection analyzer.
  • Online Ammonia Ammonium Ion-selective Electrodes Water Quality Monitoring RS485 4-20mA CS6714AD

    Online Ammonia Ammonium Ion-selective Electrodes Water Quality Monitoring RS485 4-20mA CS6714AD

    Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.The CS6714AD ammonium ion selective electrode is an effective method to measure the ammonium ion content in the sample. Ammonium ion selective electrodes are also often used in online instruments, such as industrial online ammonium ion content monitoring. Ammonium ion selective electrode has the advantages of simple measurement, fast and accurate response. It can be used with PH meter, ion meter and online ammonium ion analyzer, and also used in electrolyte analyzer, and ion selective electrode detector of flow injection analyzer.
  • Factory Sales Online Ammonia Potassium ion Analyzer Meter 3/4NPT for wastewater CS6712AD

    Factory Sales Online Ammonia Potassium ion Analyzer Meter 3/4NPT for wastewater CS6712AD

    Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices.The CS6712AD potassium ion selective electrode is an effective method to measure the potassium ion content in the sample. Potassium ion selective electrodes are also often used in online instruments, such as industrial online potassium ion content monitoring. , Potassium ion selective electrode has the advantages of simple measurement, fast and accurate response. It can be used with PH meter, ion meter and online potassium ion analyzer, and also used in electrolyte analyzer, and ion selective electrode detector of flow injection analyzer.
  • Water Online Digital RS485 Chloride Ion Selective Sensor for Water Monitoring CS6711AD

    Water Online Digital RS485 Chloride Ion Selective Sensor for Water Monitoring CS6711AD

    CS6711AD digital chloride ion sensor uses a solid membrane ion selective electrode for testing fluoride ions floating in water, which is fast, simple, accurate and economical.The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy. Double salt bridge design, longer service life.The patented chloride ion probe, with an internal reference fluid at a pressure of at least 100KPa (1Bar), seeps extremely slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than the ordinary.
  • Digital Fluoride Ion Online ISE Probe for Wastewater Treatment Sensor CS6710AD

    Digital Fluoride Ion Online ISE Probe for Wastewater Treatment Sensor CS6710AD

    CS6710AD digital fluoride ion sensor uses a solid membrane ion selective electrode for testing fluoride ions floating in water, which is fast, simple, accurate and economical. The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy. Double salt bridge design, longer service life.The patented fluoride ion probe, with an internal reference fluid at a pressure of at least 100KPa (1Bar), seeps extremely slowly from the microporous salt bridge. Such a reference system is very stable and the electrode life is longer than the ordinary.
  • Digital Ammonium Nitrogen Ion Selective Sensor NH3+ pH Sensor CS6714AD

    Digital Ammonium Nitrogen Ion Selective Sensor NH3+ pH Sensor CS6714AD

    An electrochemical sensor for determining the activity or concentration of ions in a solution using a membrane potential. When it is in contact with a solution containing the measured ion, a membrane potential directly related to the activity of the ion is generated at the phase interface between its sensitive membrane and the solution. ion selective electrodes are one-half batteries (except gas-sensitive electrodes) that must be composed of complete electrochemical cells with appropriate reference electrodes.
  • Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485 CS6015DK

    Online Digital NH3-N Potassium Ion Compensation Ammonia Nitrogen Sensor RS485 CS6015DK

    On-line ammonia nitrogen sensor, no reagents required, green and non-polluting, can be monitored online in real time. Integrated ammonium, potassium (optional), pH and reference electrodes automatically compensate for potassium (optional), pH and temperature in water. It can be directly put into installation,which is more economical, environmentally friendly and convenient than traditional ammonia nitrogen analyzer. The sensor has a self-cleaning brush
    that prevents microbial adhesion, resulting in longer maintenance intervals and excellent reliability. It adopts RS485 output and supports Modbus for easy integration.
  • Digital RS485 Ammonia Nitrogen Sensor Potassium Ion Compensation NH3 NH4 CS6015D

    Digital RS485 Ammonia Nitrogen Sensor Potassium Ion Compensation NH3 NH4 CS6015D

    On-line ammonia nitrogen sensor, no reagents required, green and non-polluting, can be monitored online in real time. Integrated ammonium, potassium (optional), pH and reference electrodes automatically compensate for potassium (optional), pH and temperature in water. It can be directly put into installation, which is more economical, environmentally friendly and convenient than traditional ammonia nitrogen analyzer. The sensor has a self-cleaning brush that prevents microbial adhesion, resulting in longer maintenance intervals and excellent reliability. It adopts RS485 output and supports Modbus for easy integration.
  • pH/ORP Sensor Digital Glass pH ORP Probe Sensor Electrode CS2543D

    pH/ORP Sensor Digital Glass pH ORP Probe Sensor Electrode CS2543D

    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage. The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
  • CS2733D Digital Oxido Reduction Potential ORP Sensor Electrode Probe

    CS2733D Digital Oxido Reduction Potential ORP Sensor Electrode Probe

    Designed for common water quality. Easy to connect to PLC, DCS, industrial control computers, general purpose controllers, paperless recording instruments or touch screens and other third party devices. Sewage industrial PH combination electrode adopts annular Teflon liquid junction, gel electrolyte and special glass sensitive membrane. Fast response and high Stability.(Hot sale price Industrial high temperature ph controller meter 4-20ma ph probe/ ph sensor/ ph electrode)