Short Description:

Constant voltage principle electrode is used to measure chlorine dioxide or hypochlorous acid in water. The constant voltage measurement method is to maintain a stable potential at the electrode measuring end, and different measured components produce different current intensities under this potential.


  • Model NO.: CS5560D
  • Housing Material: Glass+POM
  • Measurement method: Potentiostatic
  • Trademark: twinno
  • Measuring Material: Double Platinum Ring

Product Detail

Product Tags

CS5560D Digital Chlorine Dioxide Sensor (Potentiostatic)

Online-Digital-Chlorine-Dioxide-Sensor-for-Disinfectant-Fluid (1)                                                         Online-Digital-Chlorine-Dioxide-Sensor-for-Disinfectant-Fluid (2)

 

Product Description

1.The constant voltage measurement method uses a secondary instrument to continuously and dynamically control the potential between the measuring electrodes, eliminating the inherent resistance and oxidation-reduction potential of the measured water sample, so that the electrode can measure the current signal and the measured water sample concentration

2.A good linear relationship is formed between them, with a very stable zero point performance, ensuring accurate and reliable measurement.

3.The constant voltage electrode has a simple structure and a glass appearance. The front end of the online residual chlorine electrode is a glass bulb, which is easy to clean and replace. When measuring, it is necessary to ensure that the water flow rate through the chlorine dioxide

 

Electrode principle characteristics

1. Power supply and output isolation design to ensure electrical safety

2. Built-in protection circuit for power supply and communication chip, strong anti-interference ability

3. With comprehensive protection circuit design, it can work reliably without additional isolation equipment

4. The circuit is built inside the electrode, which has good environmental tolerance and easier installation and operation

5. RS-485 transmission interface, MODBUS-RTU communication protocol, two-way communication, can receive remote commands

6. The communication protocol is simple and practical and extremely convenient to use

7. Output more electrode diagnostic information, more intelligent

8. The internal integrated memory can still memorize the stored calibration and setting information after power off

9. POM shell, strong corrosion resistance, PG13.5 thread, easy to install.

 

Technical feature

Technical feature