  • CS5560 CE Certification Digital Chlorine Dioxide Sensor for Waste water RS485

    CS5560 CE Certification Digital Chlorine Dioxide Sensor for Waste water RS485

    Specifications
    Measuring Range:0 - 5.000 mg/L, 0 - 20.00 mg/L
    Temperature Range:0 - 50°C
    Double liquid junction,annular liquid junction
    Temperature sensor: standard no, optional
    Housing/dimensions: glass,120mm*Φ12.7mm
    Wire: wire length 5m or agreed, terminal
    Measurement method: tri-electrode method
    Connection thread:PG13.5
    This electrode is used with a flow channel.SNEX Solid Reference System pH Sensor for Seawater Measurement
  • CS2501C orp/pHanalyzer sensor electrode with temperature for fermenter

    CS2501C orp/pHanalyzer sensor electrode with temperature for fermenter

    Designed for General application.
    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage. The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.Completely avoid various problems caused by the exchange and blockage of the liquid junctionsuch as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.

  • Water Turbidity Sensor Digital Online Rs485 Turbidity Sensor Water Quality Turbidity Meter CS7820D

    Water Turbidity Sensor Digital Online Rs485 Turbidity Sensor Water Quality Turbidity Meter CS7820D

    Introduction:
    The principle of the turbidity sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity value. According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.
  • Sewage Water Treatment Quality Monitoring RS485 Oxygen Demand COD Sensor CS6602D

    Sewage Water Treatment Quality Monitoring RS485 Oxygen Demand COD Sensor CS6602D

    Introduction:
    COD sensor is a UV absorption COD sensor, combined with a lot of application experience, based on the original basis of a number of upgrades, not only the size is smaller, but also the original separate cleaning brush to do one, so that the installation is more convenient, with higher reliability.It does not need reagent, no pollution, more economic and environmental protection.On-line uninterrupted water quality monitoring.Automatic compensation for turbidity interference, with automatic cleaning device, even if long-term monitoring still has excellent stability.
  • Digital Automatic Ph Orp Transmitter Ph Sensor Controller online Tester T6000

    Digital Automatic Ph Orp Transmitter Ph Sensor Controller online Tester T6000

    Function
    Industrial on-line PH/ORP meter is an on-line water quality monitoring and control instrument with microprocessor. PH electrodes or ORP electrodes of different types are widely used in power plant, petrochemical industry, metallurgical electronics, mining industry, paper industry, biological fermentation engineering, medicine, food and beverage, environmental water treatment, aquaculture, modern agriculture, etc. The pH (acid, alkalinity) value, ORP (oxidation,reduction potential) value and temperature value of aqueous solution were continuously monitored and controlled.
  • Industrial Residual Online Free Chlorine Analyzer 4-20ma Chlorine Meter Sensor Electrode  CS5763

    Industrial Residual Online Free Chlorine Analyzer 4-20ma Chlorine Meter Sensor Electrode CS5763

    CS5763 is an online intelligent residual chlorine controller produced by our company with imported technology. It uses imported components and permeable filmhead, based on the latest polarographic analysis technology, advanced production technology and surface paste technology. The application of this series of adcanced analytical techniques to ensure the stability, reliability and accuracy of the long-term work of the instrument.Widely used in drinking water, bottling water, electricity, medicine, chemical, food, pulp &paper, swimming pool,water treatment industry.
  • Industrial Online Analyzer Ammonia Nitrogen Sensor Digital RS485 CS6714SD

    Industrial Online Analyzer Ammonia Nitrogen Sensor Digital RS485 CS6714SD

    Digital ISE Sensor Series CS6714SD Ammonium Ion sensor is solid membrane ion selective electrodes, used to test ammonium ions in water, which can be fast, simple, accurate and economical;The design adopts the principle of single-chip solid ion selective electrode, with high measurement accuracy;PTEE large-scale seepage interface, not easy to block, anti-pollution Suitable for wastewater treatment in the semiconductor industry, photovoltaics, metallurgy, etc. and pollution source discharge monitoring;High-quality imported single chip, accurate zero point potential without drift.
  • Industrial lab Water Glass Electrode PH sensor Conductivity Probe EC DO ORP CS1529

    Industrial lab Water Glass Electrode PH sensor Conductivity Probe EC DO ORP CS1529

    Designed for seawater environment.
    The outstanding application of SNEX CS1529 pH electrode in seawater pH measurement.
    1.Solid-state liquid junction design: The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
    2.Anti-corrosion material: In the strongly corrosive seawater, the SNEX CS1529 pH electrode is made of marine titanium alloy material to ensure the stable performance of the electrode.
  • High Precision DO Electrode Fluorescence Transmitter with Controller Digital T6046

    High Precision DO Electrode Fluorescence Transmitter with Controller Digital T6046

    Thank you for your support. Please read this manual carefully before use.The correct use will maximize the performance and advantages of the product, and bring you a good experience.When receiving the instrument, please open the package carefully, check whether the instrument and accessories are damaged by transportation and whether the accessories are complete. If anyabnormalities are found, please contact our after-sales service department or regional customer service center, and keep the package for return processing.This instrument is an analytical measurement and control instrument with highly precision.Only skilled,trained or authorized person should carry out installation, setup and operation of the instrument.Ensure that the power cable is physically separated from the
    power supply when connection or repair.Once the safety problem occurs, make sure that the power to the instrument is off and disconnected.
  • T9003 Total Nitrogen On-line Automatic Monitor

    T9003 Total Nitrogen On-line Automatic Monitor

    Product Overview:
    Total nitrogen in water mainly comes from decomposition products of nitrogen-containing organic matter in domestic sewage by microorganisms, industrial wastewater such as coking synthetic ammonia, and farmland drainage. When the total nitrogen content in water is high, it is toxic to fish and harmful to human beings in varying degrees. The determination of total nitrogen in water is helpful to evaluate the pollution and self-purification of water, so total nitrogen is an important indicator of water pollution.
    The analyzer can work automatically and continuously for a long time without attendance according to the site settings. It is widely used in industrial pollution source discharge wastewater, municipal sewage treatment plant wastewater, environmental quality surface water and other occasions. According to the complexity of site test conditions, the corresponding pretreatment system can be selected to ensure the test process is reliable,test results are accurate, and fully meet the needs of different occasions.
    This method is suitable for wastewater with total nitrogen in the range of 0-50mg/L. Excessive calcium and magnesium ions, residual chlorine or turbidity may interfere with the measurement.
  • T9001 Ammonia Nitrogen On-line Automatic Monitoring

    T9001 Ammonia Nitrogen On-line Automatic Monitoring

    1.Product Overview:
    Ammonia nitrogen in water refers to ammonia in the form of free ammonia, which mainly comes from decomposition products of nitrogen-containing organic matter in domestic sewage by microorganisms, industrial wastewater such as coking synthetic ammonia, and farmland drainage. When the content of ammonia nitrogen in water is high, it is toxic to fish and harmful to human beings in varying degrees. The determination of ammonia nitrogen content in water is helpful to evaluate the pollution and self-purification of water, so ammonia nitrogen is an important indicator of water pollution.
    The analyzer can work automatically and continuously for a long time without attendance according to the site settings. It is widely used in industrial pollution source discharge wastewater, municipal sewage treatment plant wastewater, environmental quality surface water and other occasions. According to the complexity of site test conditions, the corresponding pretreatment system can be selected to ensure the test process is reliable,test results are accurate, and fully meet the needs of different occasions.
    This method is suitable for wastewater with ammonia nitrogen in the range of 0-300 mg/L. Excessive calcium and magnesium ions, residual chlorine or turbidity may interfere with the measurement.
  • T9000 CODcr Water Quality On-line Automatic Monitor

    T9000 CODcr Water Quality On-line Automatic Monitor

    Product Overview:
    Chemical oxygen demand (COD) refers to the mass concentration of oxygen consumed by oxidants when oxidizing organic and inorganic reducing substances in water samples with strong oxidants under certain conditions. COD is also an important index reflecting the degree of pollution of water by organic and inorganic reducing substances.
    The analyzer can work automatically and continuously for a long time without attendance according to the site settings. It is widely used in industrial pollution source discharge wastewater, industrial process wastewater, industrial sewage treatment plant wastewater, municipal sewage treatment plant wastewater and other occasions. According to the complexity of site test conditions, the corresponding pretreatment system can be selected to ensure the test process is reliable,test results are accurate, and fully meet the needs of different occasions
  • CS6080D Ultrasonic Sludge Level Meter Solid Wireless Water Level Sensor analog

    CS6080D Ultrasonic Sludge Level Meter Solid Wireless Water Level Sensor analog

    ultrasonic level transmitter is featured by strong anti-interference performance; free setting of upper and lower limits and online output regulation, on-site indication. The cover, made of waterproof engineering plastics, is small and firm with ABS probe. Therefore, it is applicable for various fields concerning level measuring and monitoring.
  • Digital Water Liquid Level Meter Ultrasonic Level Meter Sensor CS6085D

    Digital Water Liquid Level Meter Ultrasonic Level Meter Sensor CS6085D

    Intelligent integrated measuring instrument is a transducer and built-in intelligent circuit control system of integrated measurement instrument, is to measure the probe surface to liquid, object surface distance, is a contactless, high reliability, high cost performance, easy installation and maintenance material, liquid level measurement instrument, widely used in non-contact measurement distance, reliable application to measuring the surface position of water, sewage, glue, mud or open channel flow, etc.
  • Online Chlorophyll Sensor RS485 Output Usable on Multiparameter Sonda CS6400D

    Online Chlorophyll Sensor RS485 Output Usable on Multiparameter Sonda CS6400D

    The principle of CS6400D Chlorophyll Sensor is using the characteristics of chlorophyll A who has absorption peaks and emission peaks in the spectrum. The
    absorption peaks emit monochromatic light into the water,chlorophyll A in the water absorbs the energy of monochromatic light,releasing monochromatic light of emission peak of another wavelength. The light intensity emitted by cyanobacteria is proportional to the content of chlorophyll A in water.