Products

  • Online Chlorophyll Sensor RS485 Output Usable on Multiparameter CS6401

    Online Chlorophyll Sensor RS485 Output Usable on Multiparameter CS6401

    Based on the fluorescence of the pigments to measurement the target parameters , it can be identified before the impact of algal bloom.No need for extraction or other treatment, rapid detection, to avoid the impact of shelving water samples;Digital sensor, strong anti-interference ability, long transmission distance;Standard digital signal output can be integrated and networked with other devices without controller. Installation of sensors on site is convenient and fast, realizing plug and play.
  • BA200 Digital Blue-green Algae Sensor Probe in Water

    BA200 Digital Blue-green Algae Sensor Probe in Water

    The portable blue-green algae analyzer is composed of a portable host and a portable blue-green algae sensor. By taking advantage of the characteristic that cyanobacteria have absorption peak and emission peak in the spectrum, they emit monochromatic light of specific wavelength to the water. Cyanobacteria in the water absorb the energy of the monochromatic light and release monochromatic light of another wavelength. The light intensity emitted by blue-green algae is proportional to the content of cyanobacteria in the water.
  • Nitrate Ion Selective Electrode For Waste Water Treatment Monitoring CS6720

    Nitrate Ion Selective Electrode For Waste Water Treatment Monitoring CS6720

    Our Ion Selective Electrodes have several advantages over colorimetric, gravimetric, and other methods:
    They can be used from 0.1 to 10,000 ppm.
    The ISE electrode bodies are shock-proof and chemically-resistant.
    The Ion Selective Electrodes, once calibrated, can monitor concentration continuously and analyze the sample within 1 to 2 minutes.
    The Ion Selective Electrodes can be placed directly into the sample without sample pretreatment or destruction of the sample.
    Best of all, Ion Selective Electrodes are inexpensive and great screening tools for identifying dissolved salts in samples.
  • CS6720SD Digital RS485 Nitrate Ion Selective Sensor NO3- Electrode Probe 4~20mA Output

    CS6720SD Digital RS485 Nitrate Ion Selective Sensor NO3- Electrode Probe 4~20mA Output

    Ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive
    membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions.
  • T4046 Fluorescence Online Dissolved Oxygen Meter Analyzer For Sewage Treatment

    T4046 Fluorescence Online Dissolved Oxygen Meter Analyzer For Sewage Treatment

    Industrial online dissolved oxygen meter is an online water quality monitor and control instrument with microprocessor. The instrument is equipped with fluorescent dissolved oxygen sensors. The online dissolved oxygen meter is a highly intelligent online continuous monitor. It can be equipped with fluorescent electrodes to automatically achieve a wide range of ppm measurement. It is a special instrument for detecting oxygen content in liquids in environmental protection sewage related industries.
  • T4042 Industrial Online Dissolved Oxygen Meter DO Meter

    T4042 Industrial Online Dissolved Oxygen Meter DO Meter

    Industrial online dissolved oxygen meter is an online water quality monitor and control instrument with microprocessor. The instrument is equipped with different types of dissolved oxygen sensors. It is widely used in power plants, petrochemical industry, metallurgical electronics, mining, paper industry, food and beverage industry, environmental protection water treatment, aquaculture and other industries. The dissolved oxygen value and temperature value of water solution are continuously monitored and controlled.
  • CS5560 CE Certification Digital Chlorine Dioxide Sensor for Waste water RS485

    CS5560 CE Certification Digital Chlorine Dioxide Sensor for Waste water RS485

    Specifications
    Measuring Range:0 - 5.000 mg/L, 0 - 20.00 mg/L
    Temperature Range:0 - 50°C
    Double liquid junction,annular liquid junction
    Temperature sensor: standard no, optional
    Housing/dimensions: glass,120mm*Φ12.7mm
    Wire: wire length 5m or agreed, terminal
    Measurement method: tri-electrode method
    Connection thread:PG13.5
    This electrode is used with a flow channel.SNEX Solid Reference System pH Sensor for Seawater Measurement
  • TUS200 Sewage Treatment Portable Turbidity Tester Monitor Analyzer

    TUS200 Sewage Treatment Portable Turbidity Tester Monitor Analyzer

    Portable turbidity tester can be widely used in environmental protection departments, tap water, sewage, municipal water supply, industrial water, government colleges and universities, pharmaceutical industry, health and disease control and other departments of the determination of turbidity, not only for the field and on-site rapid water quality emergency testing, but also for laboratory water quality analysis.
  • CH200 Portable chlorophyll analyzer

    CH200 Portable chlorophyll analyzer

    Portable chlorophyll analyzer is composed of portable host and portable chlorophyll sensor.Chlorophyll sensor is using leaf pigment absorption peaks in spectra and emission peak of the properties, in the spectrum of chlorophyll absorption peak emission monochromatic light exposure to water, the chlorophyll in the water absorption of light energy and release another emission peak wavelength of monochromatic light, chlorophyll, the emission intensity is proportional to the content of chlorophyll in water.
  • CS2668 ORP Sensor Ph Probe Sensor Industrial Lab Water Conductivity

    CS2668 ORP Sensor Ph Probe Sensor Industrial Lab Water Conductivity

    Designed for Hydrofluoric acid environment.
    The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of hydrofluoric acid environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
  • CS2701 4-20mA RS485 Modbus water ORP Electrode

    CS2701 4-20mA RS485 Modbus water ORP Electrode

    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage.
    The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.
    High-strength glass bulb design, the glass appearance is stronger.
    The electrode adopts low noise cable, the signal output is farther and more stable
    Large sensing bulbs increase the ability to sense hydrogen ions, and perform well in common water quality environment media.
  • CS2500C Industrial Orp Meter High Quality Factory Price ORP Controller Multiparameter Meter

    CS2500C Industrial Orp Meter High Quality Factory Price ORP Controller Multiparameter Meter

    Designed for General application.
    The electrode is made of ultra-bottom impedance-sensitive glass film, and it also has the characteristics of fast response, accurate measurement, good stability, and not easy to hydrolyze in the case of General application environment media. The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.

  • CS2501C orp/pHanalyzer sensor electrode with temperature for fermenter

    CS2501C orp/pHanalyzer sensor electrode with temperature for fermenter

    Designed for General application.
    Double salt bridge design, double layer seepage interface, resistant to medium reverse seepage. The ceramic pore parameter electrode oozes out of the interface and is not easy to be blocked, which is suitable for monitoring of common water quality environmental media.Completely avoid various problems caused by the exchange and blockage of the liquid junctionsuch as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.

  • CS2503C/CS2503CT  Orp Controller Multiparameter Meter High Quality Tester

    CS2503C/CS2503CT Orp Controller Multiparameter Meter High Quality Tester

    Designed for seawater environment.
    The outstanding application of pH electrode in seawater pH measurement.
    1.Solid-state liquid junction design: The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
    2.Anti-corrosion material: In the strongly corrosive seawater, the CS2503C/CS2503CT pH electrode is made of marine titanium alloy material to ensure the stable performance of the electrode.

  • CS2505C/CS2505CT ORP Meter High Quality Digital pH/ORP Tester TDS / Salinity / Resistivity Meter

    CS2505C/CS2505CT ORP Meter High Quality Digital pH/ORP Tester TDS / Salinity / Resistivity Meter

    Designed for Sodium hypochlorite solution.
    The outstanding application of pH electrode in seawater pH measurement.
    1.Solid-state liquid junction design: The reference electrode system is a non-porous, solid, non-exchange reference system. Completely avoid various problems caused by the exchange and blockage of the liquid junction,such as the reference electrode is easy to be polluted, reference vulcanization poisoning, reference loss and other problems.
    2.Anti-corrosion material: In the strongly corrosive seawater, the CS2505C/CS2505CT pH electrode is made of marine titanium alloy material to ensure the stable performance of the electrode.