Products
-
Online Chlorine Dioxide Meter T6553
Online chlorine dioxide meter is a microprocessor-based water quality
online monitoring control instrument. -
CS6530 Potentiostatic Dissolved Ozone Sensor Analyser
Specifications
Measuring Range:0 - 5.000 mg/L, 0 - 20.00 mg/L Temperature Range:0 - 50°C
Double liquid junction,annular liquid junction Temperature sensor: standard no, optional Housing/dimensions: glass,120mm*Φ12.7mm Wire: wire length 5m or agreed, terminal Measurement method: tri-electrode method Connection thread:PG13.5 -
Online Dissolved Ozone Meter T4058 Analyser
Online dissolved ozone meter is a microprocessor-based water quality online monitoring control instrument.
Typical Use
This instrument is widely used in online monitoring of water supply, tap water, rural drinking water, circulating water, washing film water, disinfectant water, pool water. It continuous monitoring and control water quality disinfection (ozone generator matching) and other industrial processes.
Features
1. Large display, standard 485 communication, with online and offline alarm, 98*98*120mm meter size, 92.5*92.5mm hole size,3.0 inch large screen display.
2. The data curve recording function is installed, the machine replaces the manual meter reading, and the query range is arbitrarily specified, so that the data is no longer lost.
3. Built-in various measurement functions, one machine with multiple functions, meeting the requirements of various measurement standards. -
Online Dissolved Ozone Meter Analyser T6058
Online Dissolved Ozone meter is a microprocessor-based water quality online monitoring control instrument. It is widely used in drinking water treatment plants, drinking water distribution networks, swimming pools, water treatment projects, sewage treatment, water disinfection and other industrial processes. It continuous monitoring and control Dissolved Ozone value in aqueous solution. -
Online Residual Chlorine Meter T4050
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument. -
Online Membrane Residual Chlorine Meter T4055
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument. multiparameter controller can monitor real-time online for 7 * 24 hours, the power supply AC220V, output signal RS485, can customize relay output signal. it can connect different sensors, up to 12 sensors, it can connect pH, ORP, conductivity, TDS, salinity, dissolved oxygen, turbidity, TSS,MLSS,COD, color, PTSA, transparency, oil in water, chlorophyll, blue-green algae, ISE(ammonium, nitrate, calcium, fluoride, chloride, potassium,sodium, copper, etc.)RS485 modbus output signal
Data storage function
24-hour real-time measurement
Download data through USB interface
Data can be viewed through mobile APP or website
Can connect up to 12 sensors -
Online Membrane Residual Chlorine Meter T6055
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument. -
Online Residual Chlorine Meter T6550
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument.ndustrial online ozone monitor is a water quality online monitoring and control instrument with microprocessor. The instrument is widely used in drinking water treatment plants, drinking water distribution networks, swimming pools, water quality treatment projects, sewage treatment, water quality disinfection (ozone generator matching) and other industrial processes to continuously monitor and control the ozone value in the aqueous solution.
Constant voltage principle
English menu, easy operation
Data storage function
IP68 protection, waterproof
Quick response, high precision
7*24 hours continuous monitoring
4-20mA output signal
Support RS-485, Modbus/RTU protocol
Relay output signal,can set high and low alarm point
LCD display, muti-parameter display current time, output current, measure value
No need electrolyte, no need replace the membrane head, easy maintenance -
Online Membrane Residual Chlorine Meter T6555
Online residual chlorine meter is a microprocessor-based water quality online monitoring control instrument. -
Online Suspended Solids Meter T4075
The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration.According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.This instrument is an analytical measurement and control instrument with highly
precision.Only skilled,trained or authorized person should carry out installation, setup and operation of the instrument.Ensure that the power cable is physically separated from the power supply when connection or repair.Once the safety problem occurs, make sure that the power to the instrument is off and disconnected. -
Online Suspended Solids Meter T6075
The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration.According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration.This instrument is an analytical measurement and control instrument with highly
precision.Only skilled,trained or authorized person should carry out installation, setup and operation of the instrument.Ensure that the power cable is physically separated from the power supply when connection or repair.Once the safety problem occurs, make sure that the power to the instrument is off and disconnected. -
Online Suspended Solids Meter T6575
The principle of the sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the sludge concentration.
According to ISO7027 infrared double-scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration. -
Online Turbidity Meter T4070
The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.
Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and calibration. -
Online Turbidity Meter T6070
The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment. -
Online Turbidity Meter T6570
The principle of the turbidity/sludge concentration sensor is based on the combined infrared absorption and scattered light method. The ISO7027 method can be used to continuously and accurately determine the turbidity or sludge concentration. According to ISO7027 infrared double- scattering light technology is not affected by chromaticity to determine the sludge concentration value. The self-cleaning function can be selected according to the use environment.
Stable data, reliable performance; built-in self-diagnosis function to ensure accurate data; simple installation and