Products

  • T4010F Fluoride Ion Monitor

    T4010F Fluoride Ion Monitor

    Industrial Online Ion Monitor is a microprocessor-based water quality online monitoring and control instrument. Equipped with various types of ion electrodes, it is widely used in power plants, petrochemicals, metallurgy and electronics, mining, papermaking, bioprocessing, pharmaceuticals, food and beverage, and environmental water treatment. It continuously monitors and controls the ion concentration values in aqueous solutions.The industrial online ion monitor is a microprocessor-based water quality online monitoring and control instrument. Equipped with various types of ion-selective electrodes, it is widely used in power plants, petrochemicals, metallurgy, electronics, mining, papermaking, bio-fermentation engineering, pharmaceuticals, food and beverage, and environmental water treatment. It enables continuous monitoring and control of ion concentrations in aqueous solutions.x
  • CS6718A Calcium Sensor Fluoride Chloride Calcium Sensor Analyzer

    CS6718A Calcium Sensor Fluoride Chloride Calcium Sensor Analyzer

    The calcium electrode is a PVC sensitive membrane calcium ion selective electrode with organic phosphorous salt as the active material, used to measure the concentration of Ca2+ ions in the solution.
    Application of calcium ion: The calcium ion selective electrode method is an effective method to determine the calcium ion content in the sample. The calcium ion selective electrode is also often used in online instruments, such as industrial online calcium ion content monitoring, calcium ion selective electrode has the characteristics of simple measurement, fast and accurate response, and can be used with pH and ion meters and online calcium ion analyzers. It is also used in ion selective electrode detectors of electrolyte analyzers and flow injection analyzers.
    Calcium ion selective electrode method for determination of calcium ions in high-pressure steam boiler feedwater treatment in power plants and steam power plants, calcium ion selective electrode method for determination of calcium ions in mineral water, drinking water, surface water, and seawater, calcium ion selective electrode method to determine calcium ions in tea, honey, feed, milk powder and other agricultural products: determine calcium ions in saliva, serum, urine and other biological samples.

  • W8088CA  Hardness (Calcium Ion) Monitor

    W8088CA Hardness (Calcium Ion) Monitor

    The industrial online ion monitor is a microprocessor-based water quality online monitoring and control instrument. Equipped with various types of ion-selective electrodes, it is widely used in power plants, petrochemicals, metallurgy, electronics, mining, papermaking, bio-fermentation engineering, pharmaceuticals, food and beverage, and environmental water treatment. It enables continuous monitoring and control of ion concentrations in aqueous solutions.
  • CS5530CD Digital Free Chlorine Sensor

    CS5530CD Digital Free Chlorine Sensor

    CS5530CD digital free chlorine sensor adopts advanced non-film voltage sensor, no need to replace the diaphragm and agent, stable performance, simple maintenance. It has the characteristics of high sensitivity, rapid response, accurate measurement, high stability, superior repeatability, easy maintenance and multi-function, and can accurately measure the free chlorine value in solution. It is widely used for automatic dosing of circulating water, chlorination control of swimming pool, continuous monitoring and control of residual chlorine content in water solution of drinking water treatment plant, drinking water distribution network, swimming pool and hospital wastewater.
  • CS5560CD Digital Chlorine Dioxide Sensor

    CS5560CD Digital Chlorine Dioxide Sensor

    digital chlorine dioxide sensor adopts advanced non-film voltage sensor, no need to replacethe diaphragm and agent, stable performance, simple maintenance. It has the characteristics of highsensitivity, rapid response, accurate measurement, high stability, superior repeatability, easy maintenanceand multi-function, and can accurately measure the chlorine dioxide value in solution. It is widely usedfor automatic dosing of circulating water, chlorination control of swimming pool, continuousmonitoring and control of chlorine dioxide content in water solution of drinking water treatment plant,drinking water distribution network, swimming pool and hospital wastewater.
  • CS6530CD Digital Dissolved Ozone Sensor

    CS6530CD Digital Dissolved Ozone Sensor

    The electrode system consists of three electrodes to address issues related to the working electrode and counter electrode failing to maintain a constant electrode potential, which can lead to increased measurement errors. By incorporating a reference electrode, the three-electrode system of the residual chlorine electrode is established. This system allows for continuous adjustment of the voltage applied between the working electrode and the reference electrode by utilizing the reference electrode potential and voltage control circuit. By maintaining a constant potential difference between the working electrode and the reference electrode, this setup offers benefits such as high measurement accuracy, prolonged working life, and reduced need for frequent calibration.
  • CS5732CDF Free Chlorine Sensor

    CS5732CDF Free Chlorine Sensor

    The electrode system consists of three electrodes to address issues related to the working electrode and counter electrode failing to maintain a constant electrode potential, which can lead to increased measurement errors. By incorporating a reference electrode, the three-electrode system of the residual chlorine electrode is established. This system allows for continuous adjustment of the voltage applied between the working electrode and the reference electrode by utilizing the reference electrode potential and voltage control circuit. By maintaining a constant potential difference between the working electrode and the reference electrode, this setup offers benefits such as high measurement accuracy, prolonged working life, and reduced need for frequent calibration.
  • CS6712A Potassium Sensor (K+ )

    CS6712A Potassium Sensor (K+ )

    The potassium ion selective electrode is an effectivemethod to measure the potassium ion content in thesample. Potassium ion selective electrodes are alsooften used in online instruments, such as industrialonline potassium ion content monitoring. , Potassiumion selective electrode has the advantages of simplemeasurement, fast and accurate response. It can beused with PH meter, ion meter and online potassiumion analyzer, and also used in electrolyte analyzer, andion selective electrode detector of flow injectionanalyzer.
  • ISE Sensor Calcium Ion Water Hardness Electrode CS6518A Calcium Ion Electrode

    ISE Sensor Calcium Ion Water Hardness Electrode CS6518A Calcium Ion Electrode

    The Hardness (Calcium Ion) Selective Electrode is a vital analytical sensor designed for the direct and rapid measurement of calcium ion (Ca²⁺) activity in aqueous solutions. While often termed a "hardness" electrode, it specifically quantifies free calcium ions, which are the primary contributor to water hardness. It is extensively used in environmental monitoring, industrial water treatment (e.g., boiler and cooling systems), beverage production, and aquaculture, where precise calcium control is crucial for process efficiency, equipment scaling prevention, and biological health.
    The sensor typically employs a liquid or polymer membrane containing a selective ionophore, such as ETH 1001 or other proprietary compounds, which preferentially complexes with calcium ions. This interaction creates a potential difference across the membrane relative to an internal reference electrode. The measured voltage follows the Nernst equation, providing a logarithmic response to calcium ion activity within a wide concentration range (typically from 10⁻⁵ to 1 M). Modern versions are robust, often featuring solid-state designs suitable for both laboratory analysis and continuous online process monitoring.
    A key advantage of this electrode is its ability to deliver real-time measurements without time-consuming wet chemistry, such as complexometric titrations. However, careful calibration and sample conditioning are essential. The ionic strength and pH of samples must often be adjusted using a special ionic strength adjuster/buffer to stabilize pH and mask interfering ions like magnesium (Mg²⁺), which can affect the reading in some designs. When properly maintained and calibrated, the calcium ion-selective electrode offers a reliable, efficient, and cost-effective method for dedicated hardness control and calcium analysis across numerous applications.

  • CS6714A Ammonium Sensor (NH4+)

    CS6714A Ammonium Sensor (NH4+)

    Ion selective electrode is a kind of electrochemical sensor that uses membrane potential to measure the activity or concentration of ions in the solution. When it comes into contact with the solution containing the ions which are to be measured, it will generate contact with the sensor at the interface between its sensitive membrane and the solution. Ion activity is directly related to membrane potential. Ion selective electrodes are also called membrane electrodes. This type of electrode has a special electrode membrane that selectively responds to specific ions. The relationship between the potential of the electrode membrane and the ion content to be measured conforms to the Nernst formula. This type of electrode has the characteristics of good selectivity and short equilibrium time, making it the most commonly used indicator electrode for potential analysis.
  • CS6710 Fluoride Ion Sensor

    CS6710 Fluoride Ion Sensor

    The fluoride ion selective electrode is a selective electrode sensitive to the concentration of fluoride ion, the most common one is the lanthanum fluoride electrode.
    Lanthanum fluoride electrode is a sensor made of lanthanum fluoride single crystal doped with europium fluoride with lattice holes as the main material. This crystal film has the characteristics of fluoride ion migration in the lattice holes.
    Therefore, it has very good ion conductivity. Using this crystal membrane, the fluoride ion electrode can be made by separating two fluoride ion solutions. The fluoride ion sensor has a selectivity coefficient of 1.
    And there is almost no choice of other ions in the solution. The only ion with strong interference is OH-, which will react with lanthanum fluoride and affect the determination of fluoride ions. However, it can be adjusted to determine the sample pH <7 to avoid this interference.
  • CS6520 Nitrate electrode

    CS6520 Nitrate electrode

    All of our Ion Selective (ISE) electrodes are available in many shapes and lengths to fit a wide variety of applications.
    These Ion Selective Electrodes are designed to work with any modern pH/mV meter, ISE/concentration meter, or suitable on-line instrumentation.
    The nitrite ion-selective electrode (ISE) is a specialized analytical sensor designed for the direct potentiometric measurement of nitrite ion (NO₂⁻) concentration in aqueous solutions. It is a critical tool in environmental monitoring, water treatment, food safety, and agricultural science, where nitrite levels serve as a key indicator of water pollution, process control in wastewater denitrification, and food preservation quality.
  • CS6720 Nitrate electrode

    CS6720 Nitrate electrode

    All of our Ion Selective (ISE) electrodes are available in many shapes and lengths to fit a wide variety of applications.
    These Ion Selective Electrodes are designed to work with any modern pH/mV meter, ISE/concentration meter, or suitable on-line instrumentation.
  • CS6521 Nitrite electrode

    CS6521 Nitrite electrode

    The nitrite ion-selective electrode (ISE) is a specialized analytical sensor designed for the direct potentiometric measurement of nitrite ion (NO₂⁻) concentration in aqueous solutions. It is a critical tool in environmental monitoring, water treatment, food safety, and agricultural science, where nitrite levels serve as a key indicator of water pollution, process control in wastewater denitrification, and food preservation quality.
    The core of a modern nitrite ISE is typically a polymer membrane or a crystalline solid-state sensor body impregnated with a nitrite-selective ionophore. This proprietary chemical component selectively binds nitrite ions, creating a potential difference across the membrane relative to a stable internal reference electrode. This measured voltage is logarithmically proportional to the activity (and thus concentration) of nitrite ions in the sample according to the Nernst equation.
    A significant advantage of the nitrite ISE is its ability to provide rapid, real-time analysis without the need for complex sample preparation or colorimetric reagents required by traditional methods like the Griess assay. Modern electrodes are designed for both laboratory benchtop use and integration into online, continuous monitoring systems. However, careful calibration across the intended measurement range and awareness of potential interferences from ions like chloride or nitrate (depending on the membrane selectivity) are essential for obtaining accurate results. When used correctly, it offers a robust, cost-effective solution for the dedicated, routine measurement of nitrite.
    All of our Ion Selective (ISE) electrodes are available in many shapes and lengths to fit a wide variety of applications.
    These Ion Selective Electrodes are designed to work with any modern pH/mV meter, ISE/concentration meter, or suitable on-line instrumentation.
  • CS6512 Potassium Ion Sensor

    CS6512 Potassium Ion Sensor

    The potassium ion selective electrode is an effective method to measure the potassium ion content in the sample. Potassium ion selective electrodes are also often used in online instruments, such as industrial online potassium ion content monitoring. , Potassium ion selective electrode has the advantages of simple measurement, fast and accurate response. It can be used with PH meter, ion meter and online potassium ion analyzer, and also used in electrolyte analyzer, and ion selective electrode detector of flow injection analyzer.